2021
DOI: 10.1016/j.fusengdes.2020.112218
|View full text |Cite
|
Sign up to set email alerts
|

Real-time feedback control system for ADITYA-U horizontal plasma position stabilisation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 20 publications
(26 reference statements)
0
5
0
Order By: Relevance
“…Microwave interferometer is used for electron density measurement [22] and electron temperature is deduced from the Soft X-ray emission measurement using foil-ratio technique [24]. PMT-filter based spectroscopic systems and visible spectrometers are used for Hα and low Z impurity emission monitoring as well as plasma column boundary position measurements [10,23]. VUV spectrometers are used for high Z impurity emission measurement [23].…”
Section: Aditya-u Operations and Experimental Progressmentioning
confidence: 99%
See 2 more Smart Citations
“…Microwave interferometer is used for electron density measurement [22] and electron temperature is deduced from the Soft X-ray emission measurement using foil-ratio technique [24]. PMT-filter based spectroscopic systems and visible spectrometers are used for Hα and low Z impurity emission monitoring as well as plasma column boundary position measurements [10,23]. VUV spectrometers are used for high Z impurity emission measurement [23].…”
Section: Aditya-u Operations and Experimental Progressmentioning
confidence: 99%
“…The ADITYA-U pulse power supply is used for powering the TF, TR, and BV coils. A dual-polarity fast feedback power supply (FFPS) controlled by proportional-integral-derivative (PID) controller is used for real-time horizontal plasma position control [10]. Details of associated electronics, the data acquisition and triggering transmitter and receiver systems of ADITYA-U were described in [1].…”
Section: Aditya-u Operations and Experimental Progressmentioning
confidence: 99%
See 1 more Smart Citation
“…A field-programmable gate array-based PID controller was used for the operation of the real-time position control system [27]. A model for the ADITYA-U horizontal plasma position control was implemented in a closed loop configuration.…”
Section: Real-time Plasma Position Control In Aditya-umentioning
confidence: 99%
“…The gas puff parameters such as pulse width timing, voltage level, time for gas puff to start, number of pulses and the time gap between pulses can be adjusted as per the requirements of the experiment. Plasma position is controlled by a spectroscopic reference signal and a real time feedback control system [22]. This system simultaneously monitors the H α emissions using two vertical LoS at the same radial locations on the low and high field sides of the plasma from the bottom port of the machine.…”
Section: Methodsmentioning
confidence: 99%