First indigenously built tokamak ADITYA, operated over 2 decades with circular poloidal limiter has been upgraded to a tokamak named ADITYA Upgrade for the purpose having shape plasma operation with open divertor geometry. Experiment research in ADITYA-U has made significant progress, since last FEC 2016. After installation of PFC and standard tokamak diagnostics, the Phase-I plasma operations were conducted from December 2016 with graphite toroidal belt limiter. Purely Ohmic discharges in circular plasmas supported by Filament pre-ionization was obtained. The plasma parameters, Ip ~ 80-95 kA, duration ~ 80-180 ms with toroidal field (max.) ~ 1T and chord-averaged electron density ~ 2.5 x 10^19 m^-3 has been achieved. Being a medium sized tokamak, runaway electron (RE) generation, transport and mitigation experiments have always been one of the prime focus of ADITYA-U. MHD activities and density enhancement with H2 gas puffing studied. The Phase-I operation was completed in March 2017. The Phase-II operation preparation in ADITYA-U includes calibration of magnetic diagnostics followed by commissioning of major diagnostics and installation of baking system. After repeated cycles of baking the vacuum vessel up to ~ 130°C, the Phase-II operations resumed from February 2018 and are continuing to achieve plasma parameters close to the design parameters of circular limiter plasmas using real time plasma position control. Hydrogen gas breakdown was observed in more than ~2000 discharge including Phase-I and Phase-II operation without a single failure. Several experiments, including the primary RE control with lower E/P operation and secondary RE control with fuelling of Supersonic Molecular Beam Injection as well as sonic H2 gas puffing during current flat-top and Neon gas puffing for better plasma confinement are undergoing. The dismantling of ADITYA and reassembling of ADITYA-U along with experimental results of Phase-I and Phase-II operations from ADITYA-U will be discussed.
Short bursts (∼1 ms) of gas, injecting ∼1017–1018 molecules of hydrogen and/or deuterium, lead to the observation of cold pulse propagation phenomenon in hydrogen plasmas of the ADITYA-U tokamak. After every injection, a sharp increase in the chord-averaged density is observed followed by an increase in the core electron temperature. Simultaneously, the electron density and temperature decrease at the edge. All these observations are characteristics of cold pulse propagation due to the pulsed gas application. The increase in the core temperature is observed to depend on the values of both the chord-averaged plasma density at the instant of gas-injection and the amount of gas injected below a threshold value. Increasing the amount of gas-puff leads to higher increments in the core-density and the core-temperature. Interestingly, the rates of rise of density and temperature remain the same. The gas-puff also leads to a fast decrease in the radially outward electric field together with a rapid increase in the loop-voltage suggesting a reduction in the ion-orbit loss and an increase in Ware-pinch. This may explain the sharp density rise, which remains mostly independent of the toroidal magnetic field and plasma current in the experiment. Application of a subsequent gas-puff before the effect of the previous gas-pulse dies down, leads to an increase in the overall electron density and consequently the energy confinement time.
In order to understand the atomic and molecular processes involved in the emission of the hydrogen Balmer alpha (H α ) spectral line from tokamak plasmas, the measured radial profile of H α emissivity in ADITYA tokamak discharges has been modeled using the DEGAS2 neutral particle transport code. The radial profile of emissivity has been measured using a 1.0 m multi-track spectrometer and with PMT array based space-resolved visible spectroscopic diagnostics involving interference filters. The radial profile of the neutral hydrogen density has been obtained using the DEGAS2 code by reproducing the experimentally observed H α emissivity profile. It has been found that the neutral density falls by 80-200 times at the plasma center compared to its maximum value at the plasma edge near the limiter (ρ = 0.92). Detailed investigation of the contributions of atomic and molecular processes involved in H α emission reveals the significant presence of hydrogen molecules and molecular ions within ∼4 cm of the limiter radius. The contributions from processes involving H + 2 ions are found to be higher than those from the molecular hydrogen dissociation with H + 2 dissociative recombination dominating over H + 2 dissociation at the extreme edge of the plasma.
Since the 2018 IAEA-FEC conference, in addition to expanding the parameter horizons of the ADITYA-U machine, emphasis has been given to dedicated experiments on inductively driven particle injection (IPI) for disruption studies, runaway electron (RE) dynamics and mitigation, plasma rotation reversal, radiative-improved modes using Ne and Ar injection, modulation of magneto–hydrodynamic modes, edge turbulence using periodic gas puffs and electrode biasing (E-B). Plasma parameters close to the design parameters of circular plasmas with H2 and D2 as fuel have been realized, and the shaped plasma operation has also been initiated. Consistent plasma discharges having I P ∼ 100–210 kA, t ∼ 300–400 ms, n e ∼ 3–6 × 1019 m−3, core T e ∼ 300–500 eV were achieved with a maximum B T of ∼1.5 T. The enhanced plasma parameters are the outcome of repeated cycles of baking (135 °C), followed by extensive wall conditioning, which includes pulsed glow discharge cleaning in H, He and Ar–H mixture, and lithiumization. A higher confinement time has been observed in D2 compared to H2 plasmas. Furthermore, shaped plasmas are attempted for the first time in ADITYA-U. A first of its kind inductively driven particle injection for disruption mitigation studies has been developed and operated. The injection of solid particles into the plasma core leads to a fast current quench. Two pulses of electron cyclotron resonance wave at 42 GHz are launched in a single discharge: one pulse is used for pre-ionization and the second for heating. In a novel approach, a positively biased electrode is used to confine REs after discharge termination. E-B is also used for controlling the rotation of drift-tearing modes by changing the plasma rotation. Cold pulse propagation and signatures of detachment are observed during the injection of short gas puffs. A correlation between the plasma toroidal rotation and the total radiated power has been observed with neon gas injection-induced improved confinement modes.
The spectroscopic studies of medium and high Z impurities have been the subject of interest in fusion research due to their role in mitigating plasma disruption and reducing heat load on the plasma facing components. Line emissions from these impurities provide the rotation velocity and ion temperature measurements along with the understanding of the overall impurity behavior in plasma. In the Aditya-U tokamak, the spatially resolved Ar II line emissions have been observed using a high resolution multi-track spectroscopic diagnostic consisting of a 1 m Czerny–Turner spectrometer coupled with a charge coupled device (CCD) detector using seven lines of sight viewing plasma tangentially along the toroidal direction. The spatially resolved Ar II lines at 458.96 nm have been observed. The singly ionized Ar emission peaks at the radial location of ρ = 0.8 of the plasma having a minor radius of 25 cm. Moreover, a 0.5 m UV–visible spectrometer coupled with a CCD detector and having a line of sight passing through the plasma midplane from the radial port was used to record visible Ar survey spectra within the 670–810 nm wavelength range, and all these lines have been identified for further analysis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.