2012
DOI: 10.1117/12.922184
|View full text |Cite
|
Sign up to set email alerts
|

Real-time 3D vibration measurements in microstructures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0
1

Year Published

2013
2013
2019
2019

Publication Types

Select...
3
2

Relationship

3
2

Authors

Journals

citations
Cited by 7 publications
(10 citation statements)
references
References 6 publications
0
9
0
1
Order By: Relevance
“…5) of the measurement spot captured with an integrated camera module with defined pixel size has been evaluated to estimate the focus diameter on the specimen. The spot has a diameter of <3.5 μm, which is an improvement compared with the existing three-beam technology 5 by approximately a factor of 10. The measurement spot can be positioned on an edge, corner, etch hole of a MEMS device with a reflective surface or any light scattering feature on the object.…”
Section: Analyzing the Spot Diameter Of The Impinging Beammentioning
confidence: 74%
See 2 more Smart Citations
“…5) of the measurement spot captured with an integrated camera module with defined pixel size has been evaluated to estimate the focus diameter on the specimen. The spot has a diameter of <3.5 μm, which is an improvement compared with the existing three-beam technology 5 by approximately a factor of 10. The measurement spot can be positioned on an edge, corner, etch hole of a MEMS device with a reflective surface or any light scattering feature on the object.…”
Section: Analyzing the Spot Diameter Of The Impinging Beammentioning
confidence: 74%
“…However, the formula is sufficient for most technical applications, where the (measurable) velocity of the scatter point is much lower than the velocity of light (jṽj ≪ c) and, in addition, we have measured the movement of an accurate stage to study the correctness of Eq. (1), experimentally 5 on a rough surface under presence of laser Speckle effects. Equation (1) and the schematic in Fig.…”
Section: Principle Of Laser-doppler Vibrometrymentioning
confidence: 99%
See 1 more Smart Citation
“…Future research is directed to fast 3-D identification of resonances with a 3-D vibrometry technology [32] to employ the technology demonstrated in this paper to in-plane vibrating MEMS structures or to identify 3-D motions on the wafer level in a production environment.…”
Section: Resultsmentioning
confidence: 98%
“…proportional zum Sinus des halben Detektionswinkels θ/2, skaliert mit dem Faktor κ aus(6). Würde man nur den SNR betrachten, wäre demnach ein Detektionswinkel von θ ≈ 55 • optimal.…”
unclassified