2011
DOI: 10.1016/j.aca.2011.06.011
|View full text |Cite
|
Sign up to set email alerts
|

Rapid radiochemical method for determination of actinides in emergency concrete and brick samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
28
0

Year Published

2014
2014
2016
2016

Publication Types

Select...
7

Relationship

4
3

Authors

Journals

citations
Cited by 40 publications
(28 citation statements)
references
References 17 publications
0
28
0
Order By: Relevance
“…Aqueous samples were placed into a DigiPREP vial and acidified to 3 M, suitable medium to fix of the elements on the resins, by adding 2.4 mL of concentrated HNO 3 . 3.75 g of aluminum nitrate (previously purified from traces of uranium by passing 500 mL of a 750 g L À1 solution through 3 mL of the DGA resin) was added to each sample [17]. In case of high environmental radioactive contamination, Al(NO 3 ) 3 could be used without previous purification, since a blank contamination would be negligible and subtracted without significant impact.…”
Section: Methodsmentioning
confidence: 99%
“…Aqueous samples were placed into a DigiPREP vial and acidified to 3 M, suitable medium to fix of the elements on the resins, by adding 2.4 mL of concentrated HNO 3 . 3.75 g of aluminum nitrate (previously purified from traces of uranium by passing 500 mL of a 750 g L À1 solution through 3 mL of the DGA resin) was added to each sample [17]. In case of high environmental radioactive contamination, Al(NO 3 ) 3 could be used without previous purification, since a blank contamination would be negligible and subtracted without significant impact.…”
Section: Methodsmentioning
confidence: 99%
“…Cool with ice to room temp. (U) Add 5mL 3.2 M (NH 4 ) 2 Cerium fluoride microprecipitation was used to prepare the purified actinide samples for alpha spectrometry counting. After adding 50 lg Ce, 0.5 mL 30 wt% H 2 O 2 and 1 mL 28 M HF to the Pu eluent solution and waiting 15 min, the solution was filtered using a 25 mm polypropylene filter (0.1 lm pore size disposable Resolve TM filter funnel).…”
Section: Column Load Solutionmentioning
confidence: 99%
“…TRU ? DGA Resin may also be used [2]. Rapid flow rates achieved using vacuum box technology, and stacked resin cartridges with highly selective extraction chromatographic resins significantly reduce separation times and waste volumes.…”
Section: Introductionmentioning
confidence: 98%
See 1 more Smart Citation
“…In addition to the first row transition elements, the separation of other elements found in the melt glass debris are also of interest, such as Group 1 and 2 elements and the actinides. [8][9][10][11]. Therefore, this separation of urban melt glass, which consists of both cement and glass, with the intent to separate some of the first row transition metals using DGA resin, is unique.…”
Section: Introductionmentioning
confidence: 98%