2018
DOI: 10.1016/j.jpowsour.2018.10.014
|View full text |Cite
|
Sign up to set email alerts
|

Rapid monitoring of impedance phase shifts in lithium-ion batteries for hazard prevention

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
47
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 79 publications
(48 citation statements)
references
References 32 publications
1
47
0
Order By: Relevance
“…We demonstrated recently that changes in cell impedance (Z cell ) can be measured tens of seconds before the pre-TR venting. 92 Cell impedance values are dependent on the frequencies at which they are measured. For example, in LG HG2 and Samsung SDI-26F 18650 cells, changes in impedance before the pre-TR venting are detectable at frequencies less than 10 Hz.…”
Section: Discussionmentioning
confidence: 99%
“…We demonstrated recently that changes in cell impedance (Z cell ) can be measured tens of seconds before the pre-TR venting. 92 Cell impedance values are dependent on the frequencies at which they are measured. For example, in LG HG2 and Samsung SDI-26F 18650 cells, changes in impedance before the pre-TR venting are detectable at frequencies less than 10 Hz.…”
Section: Discussionmentioning
confidence: 99%
“…The Z SEI is frequency-dependent (a wide range of frequency from 10 Hz to 1 kHz), and its quadrature component is capacitive (negative phase shifts) [251]. Srinivasan et al [253] proved that simply measuring the phase shift (φ) to estimate the temperature of the cell is feasible. Compared with deriving SEI layer resistance (R SEI ) and electrolyte resistance (R S ) [57,254], φ is easier to estimate the temperature without requiring multiple-frequency impedance, and it is well matched with measured data of the electrical equivalent circuit model [255].…”
Section: Monitoring Temperature and Voltagementioning
confidence: 99%
“…The temperature monitoring for dynamic operation should be extensively studied. Besides accurately monitoring the temperature of cells, the phase shift has proved to be an effective parameter to predict cell venting, which could be a decisive condition for best control of the batteries [253].…”
Section: Monitoring Temperature and Voltagementioning
confidence: 99%
“…However, high DC (dis)charge currents, interference from electric components, crosstalk interference, SoC and aging dependencies make it challenging to implement. So far, most research on this subject was performed under equilibrium conditions, although impedance-based temperature indication also has been applied under current flow [277,[290][291][292], and for thermal runaway monitoring [293]. However, more research efforts on the implementation of impedance-based temperature indication are necessary in order to obtain a clear understanding how accurately and fast it can be performed.…”
Section: Impedance-based Temperature Measurementsmentioning
confidence: 99%