1997
DOI: 10.1302/0301-620x.79b3.0790351
|View full text |Cite
|
Sign up to set email alerts
|

Radiological and Survival Comparison of Four Methods of Fixation of a Proximal Femoral Stem

Abstract: We compared the radiological appearances and survival of four methods of fixation of a femoral stem in 538 hips after follow-up for five or ten years. The fixation groups were: 1) press-fit shot-blasted smooth Ti-Al-V stem; 2) press-fit shot-blasted proximally ridged stem; 3) proximal hydroxyapatite (HA) coating; and 4) cementing. Survival analysis at five to ten years showed better results in the HA-coated (100% at five to six years) and cemented stems (100% at 5 to 6 years) than in the two press-fit groups.… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
24
0
1

Year Published

1998
1998
2014
2014

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 45 publications
(27 citation statements)
references
References 18 publications
1
24
0
1
Order By: Relevance
“…Calcium phosphate (CaP) coatings have been shown to promote early bone apposition at the surface of cementless orthopedic prostheses [1][2][3][4][5][6][7] and have given highly successful clinical results [8][9][10][11][12][13][14]. Plasma-sprayed hydroxyapatite (HA) coatings applied on to titanium implants have been shown to enhance the quality of bone apposition and the biomechanical fixation of prostheses [3,15].…”
Section: Introductionmentioning
confidence: 99%
“…Calcium phosphate (CaP) coatings have been shown to promote early bone apposition at the surface of cementless orthopedic prostheses [1][2][3][4][5][6][7] and have given highly successful clinical results [8][9][10][11][12][13][14]. Plasma-sprayed hydroxyapatite (HA) coatings applied on to titanium implants have been shown to enhance the quality of bone apposition and the biomechanical fixation of prostheses [3,15].…”
Section: Introductionmentioning
confidence: 99%
“…Although HA-coated implants have been investigated for more than a decade, only a few midterm results are published. 4,14 At first, our hypothesis was that we would have a lower percentage of stress-shielding with a new anatomic proximal HA-coated design of stem. We also thought that with using a HA-coated system to facilitate bone ongrowth, we would have a lower incidence of migration of PE particles and osteolysis.…”
mentioning
confidence: 99%
“…Femurschaftprothese · Zementiertechnik · Intramedullärer Druck · Mikrosonde · Hüftendoprothese Die Entwicklung der Hüftendoprothe-sen hat in zunehmendem Maße die Vorteile einer proximalen Krafteinleitung am Femur gezeigt [2,3,8]. Ausgehend von der Überlegung, dass eine physiologische Krafteinleitung im Bereich des Femurs praktisch nur im proximalen Bereich (also im Bereich der Trabekel) erfolgt [3], nicht aber im Schaftbereich (also über das Endost) kommt man heute immer mehr dazu, zementierte als auch nicht zementierte Prothesen mit proximaler Krafteinleitung und proximalem Formschluss ohne Verankerung im Schaftbereich zu entwickeln.…”
Section: Schlüsselwörterunclassified