2018
DOI: 10.1016/j.jphotochem.2017.10.025
|View full text |Cite
|
Sign up to set email alerts
|

Radiochromic gels for UV radiation measurements in 3D

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
15
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7

Relationship

4
3

Authors

Journals

citations
Cited by 23 publications
(15 citation statements)
references
References 56 publications
0
15
0
Order By: Relevance
“…Also, Pluronic F–127 has been used for numerous applications such as for the preparation of micelles as a drug delivery system for photodynamic therapy [ 28 ] or nanoparticles as antioxidant carriers to stabilize polymers [ 29 ]. Besides, as a non-toxic co-polymer, Pluronic F–127 was widely used for the encapsulation of living cells and in other biomaterials research [ 30 ]. So far, there have been several gel dosimeters for 3D radiotherapy developed on the basis of Pluronic F–127 [ 25 , 30 , 31 , 32 , 33 , 34 , 35 , 36 , 37 , 38 ].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Also, Pluronic F–127 has been used for numerous applications such as for the preparation of micelles as a drug delivery system for photodynamic therapy [ 28 ] or nanoparticles as antioxidant carriers to stabilize polymers [ 29 ]. Besides, as a non-toxic co-polymer, Pluronic F–127 was widely used for the encapsulation of living cells and in other biomaterials research [ 30 ]. So far, there have been several gel dosimeters for 3D radiotherapy developed on the basis of Pluronic F–127 [ 25 , 30 , 31 , 32 , 33 , 34 , 35 , 36 , 37 , 38 ].…”
Section: Introductionmentioning
confidence: 99%
“…Besides, as a non-toxic co-polymer, Pluronic F–127 was widely used for the encapsulation of living cells and in other biomaterials research [ 30 ]. So far, there have been several gel dosimeters for 3D radiotherapy developed on the basis of Pluronic F–127 [ 25 , 30 , 31 , 32 , 33 , 34 , 35 , 36 , 37 , 38 ].…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, many commercially used printing pastes do not form a transparent film on the textile (cloudiness and yellowing occur), which may cause readout errors. Pluronic F-127, on the other hand, is a copolymer composed of poly(propylene oxide) core and surrounding poly(ethylene oxide) blocks, which, if used as a gel matrix in radiochromic hydrogels, provides a high degree of transparency and colourlessness [ 25 , 26 , 27 ], which completely eliminates this problem. Furthermore, Pluronic F-127 is a nontoxic copolymer approved by the US Food and Drug Administration (FDA) [ 25 ], which is another reason for replacing the printing paste containing environmentally harmful chemical compounds.…”
Section: Introductionmentioning
confidence: 99%
“…So far, radiochromic hydrogels have been widely studied as dosimeters for high-resolution three-dimensional UV or ionising radiation dose distribution measurements. For this purpose, several dosimeter compositions have been tested, such as TTC-Pluronic F-127, LMG-Pluronic F-127 [ 25 , 26 ], NBT-Pluronic F-127 [ 29 ] and LCV-Pluronic F-127 [ 30 , 31 ]. In this work, we present another possibility of using such radiochromic hydrogels and, simultaneously, a new approach to the preparation of UV-sensitive textile-based sensors.…”
Section: Introductionmentioning
confidence: 99%
“…Optical computed tomography is the readout method in this case. Examples of such dosimeters include PRESAGE® plastic [34][35], gel dosimeters based on leuco-dyes and gelatine [36][37][38], and leuco-dyes or tetrazolium salts and Pluronic F-127 [39][40][41][42].…”
Section: Introductionmentioning
confidence: 99%