2020
DOI: 10.1016/j.ejmp.2019.11.014
|View full text |Cite
|
Sign up to set email alerts
|

Clinical radiotherapy application of N-vinylpyrrolidone-containing 3D polymer gel dosimeters with remote external MR-reading

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
16
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
10

Relationship

3
7

Authors

Journals

citations
Cited by 32 publications
(17 citation statements)
references
References 61 publications
0
16
0
Order By: Relevance
“…Long-term stability may be important when measurements are carried out in a remote location from the irradiation, which would require several days of transfer of the dosimeter. This was the case for another study [ 28 ], in which different polymer gel dosimeters were used for verification of a treatment planning generated plan of irradiation of a tumor requiring irradiation in a radiotherapy department in one country and then transfer to another country for MRI measurements. In such cases, the long-term stability of the polymer gel dosimeters is essential.…”
Section: Resultsmentioning
confidence: 99%
“…Long-term stability may be important when measurements are carried out in a remote location from the irradiation, which would require several days of transfer of the dosimeter. This was the case for another study [ 28 ], in which different polymer gel dosimeters were used for verification of a treatment planning generated plan of irradiation of a tumor requiring irradiation in a radiotherapy department in one country and then transfer to another country for MRI measurements. In such cases, the long-term stability of the polymer gel dosimeters is essential.…”
Section: Resultsmentioning
confidence: 99%
“…Various studies have analyzed the MRI response of polymer gels for possible application in radiotherapy dose mapping ([ 58 , 63 ] and references therein). In particular, polymer gels have been investigated for dosimetry in conformal therapy, IMRT, IMAT, IGRT, VMAT and tomotherapy [ 55 , 70 , 83 , 88 , 102 , 105 , 106 , 107 , 108 , 109 , 110 , 111 , 112 , 113 , 114 , 115 , 116 , 117 , 118 , 119 , 120 , 121 , 122 , 123 , 124 , 125 , 126 , 127 , 128 , 129 , 130 , 131 , 132 , 133 , 134 , 135 ], small photon fields [ 136 , 137 , 138 ], stereotactic radiosurgery [ 55 , 139 , 140 , 141 , 142 ], 60-cobalt source [ 143 , 144 ], brachytherapy [ 55 , 85 , 92 , 145 , ...…”
Section: Polyacrylamide Gelsmentioning
confidence: 99%
“…Different types of monomers were incorporated in the preparation of various types of polymer gels, such as N-isopropylacrylamide [ 27 ], methacrylic-acid [ 28 , 29 ], N-hydroxyethylacrylate [ 30 ], N-vinylpyrrolidone [ 31 , 32 , 33 ], Itaconic-acid [ 34 ], 2-acrylamide-2-methylpropane-sulfonic-acid sodium salt [ 35 ], N-(3-methoxypropyl)-acrylamide [ 10 , 36 ], and N -(hydroxymethyl)-acrylamide [ 8 , 37 , 38 , 39 ].…”
Section: Introductionmentioning
confidence: 99%