2008
DOI: 10.1016/j.enbuild.2007.01.019
|View full text |Cite
|
Sign up to set email alerts
|

Quantifying energy savings in daylight responsive systems: The role of dimming electronic ballasts

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
55
0
1

Year Published

2014
2014
2018
2018

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 132 publications
(57 citation statements)
references
References 18 publications
1
55
0
1
Order By: Relevance
“…In [34], they demonstrated that evaluating energy costs with different software can determine results that diverge up to 15%. On the one hand differences in results depend on the definition of indoor daylight availability, but on the other hand they depend on the control systems' modeling that neglect important factors as the specific characteristics of photosensors, luminaires, or ballasts [20][21][22][23].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In [34], they demonstrated that evaluating energy costs with different software can determine results that diverge up to 15%. On the one hand differences in results depend on the definition of indoor daylight availability, but on the other hand they depend on the control systems' modeling that neglect important factors as the specific characteristics of photosensors, luminaires, or ballasts [20][21][22][23].…”
Section: Discussionmentioning
confidence: 99%
“…Above the already mentioned studies about software validations, researchers analyzed different aspects connected to simulations: calculation affecting factors as sky model or weather data file [16][17][18], the correct modeling of complex materials or fenestration systems [6,14], the uncertainty of users' behavior [19], and the daylightlinked control modeling [20][21][22][23].…”
Section: Introductionmentioning
confidence: 99%
“…Una de las maneras más eficientes de reducir el consumo de luz eléctrica es a través del uso de la luz natural llamada luz del día (Bodart et al, 2008). El empleo de la iluminación natural vinculado con controles de iluminación artificial ha revelado, en estudios de campo, ahorros energéticos de entre un 30 y un 60 % (Li y Lam, 2001;Li et al, 2006;Kurian et al, 2008;Doulos et al, 2008).…”
Section: Introductionunclassified
“…Lighting control systems can reduce energy use from electricity by 20% or even up to 60% in certain conditions [6][7][8]. A side benefit to proper daylighting are the reduced costs for cooling, as the amount of heat generated by the lighting system is also reduced [9].…”
Section: Introductionmentioning