Evaluation of Daylight Availability for Energy Savings

Abstract: Dynamic daylight simulations are very useful instruments in daylighting design process. They allow an in depth analysis of indoor daylight availability levels and define if they are adequate to perform a particular visual task. Their results can be used to design shading devices or lighting control systems and compare different technical solutions. The use of these simulations is likely to spread in the common design practice since some regulations and green building rating systems suggest their use. This pape… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
20
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 21 publications
(20 citation statements)
references
References 20 publications
0
20
0
Order By: Relevance
“…To attain the required illuminance of 500 lx, which is the minimum requirement [38][39][40][41], in the office when sunlight fell from the required range, we made use of LED light sources. LEDs were placed by feedback from a light sensor.…”
Section: Simulation and Resultsmentioning
confidence: 99%
“…To attain the required illuminance of 500 lx, which is the minimum requirement [38][39][40][41], in the office when sunlight fell from the required range, we made use of LED light sources. LEDs were placed by feedback from a light sensor.…”
Section: Simulation and Resultsmentioning
confidence: 99%
“…Ref. [70,71] present the application of artificial intelligence to predict the availability of daylighting and use this algorithm to calculate the final energy requirements of a building. The calculation of daylight availability and its impact on energy savings are presented in Reference [72][73][74].…”
Section: Literature Reviewmentioning
confidence: 99%
“…An illuminance level of 100 lux, the DA in April onwards (Fig. 9), could be used for spatial orientation in corridors and toilets, with full daylight illuminance at higher solar angles during six months of the year according to [28] and along with complementary lighting for the rest of the year [29]. In all, this would still provide about 33% and 37% of DA for house 1 and house 2, respectively, which was calculated at 0.7 m above floor level, compared with the DA at sensor level.…”
Section: Daylight Autonomy and Illuminationmentioning
confidence: 99%
“…With the annual DA results obtained here, the amount of electricity used for lighting purposes in farm buildings for growing pigs, broilers, and laying hens could be reduced. Combining light pipes with dimmable LED lights in periods of weak DA could reduce the electricity use for lighting to an even lower level [29].…”
Section: Design Considerationsmentioning
confidence: 99%