1994
DOI: 10.1016/0378-4347(94)80093-6
|View full text |Cite
|
Sign up to set email alerts
|

Quantification of zidovudine and one of its metabolites in plasma and urine by solid-phase extraction and high-performance liquid chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2001
2001
2009
2009

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(6 citation statements)
references
References 9 publications
0
6
0
Order By: Relevance
“…At pH > 6, the recovery of AMT almost decreased to 0. Schrive and Plasse suggested an on-line SPE method to extract AZT and G-AZT from plasma and urine with a Perisorb RP8 extraction column [55]. The on-line method provided rapid sample pretreatment because it circumvented the evaporation under nitrogen flow.…”
Section: Spe With Other Columnsmentioning
confidence: 99%
“…At pH > 6, the recovery of AMT almost decreased to 0. Schrive and Plasse suggested an on-line SPE method to extract AZT and G-AZT from plasma and urine with a Perisorb RP8 extraction column [55]. The on-line method provided rapid sample pretreatment because it circumvented the evaporation under nitrogen flow.…”
Section: Spe With Other Columnsmentioning
confidence: 99%
“…The HPLC methods described in the literature for determination of AZT levels in animal and human plasma (Molema et al, 1992;Schrive and Plasse, 1994;Aymard et al, 2000;Tan and Boudinot, 2000;Clark et al, 2001;Marchei et al, 2002;Ramachandran et al, 2006;Tarinas et al, 2007;Lewis et al, 2007;Lefebvre et al, 2007) present high analysis costs of because they use sample treatment processes based on solid phase extraction or several steps of liquid-liquid extraction. These assay methods are relatively time-consuming or use expensive instrumentation not readily accessible to many groups.…”
Section: Discussionmentioning
confidence: 99%
“…These methods involve ultraviolet assay (Baig et al, 2001;Erk, 2004), liquid chromatography/tandem mass spectrometry Pereira et al, 2000;Alnouti et al, 2005;Mudigonda et al, 2008), micellar capillary electrophoresis and high-performance liquid chromatography (HPLC) with UV detection (Molema et al, 1992;Schrive and Plasse, 1994;Aymard et al, 2000;Tan and Boudinot, 2000;Clark et al, 2001;Marchei et al, 2002;Ramachandran et al, 2006;Tarinas et al, 2007;Lewis et al, 2007;Lefebvre et al, 2007). Most of the methods using HPLC with UV detection methods described until now are relatively timeconsuming or they use expensive instrumentation not readily accessible to many groups.…”
Section: Introductionmentioning
confidence: 99%
“…The latter cartridge ensured the best reproducibility of results and provided better purification of samples from interfering substances. The stage of deproteination was performed using organic solvents [29 -34], trichloroacetic acid [35], and perchloric acid [21], or by means of ultrafiltration [36,37]. Foreign macromolecules were successfully removed on a Spheron Thiol column (100´4 mm, 40 -63 mm) containing silver(I) ions [38,39].…”
Section: Thymidine Derivativesmentioning