2017
DOI: 10.1038/ejcn.2017.27
|View full text |Cite
|
Sign up to set email alerts
|

Quantification of whole-body and segmental skeletal muscle mass using phase-sensitive 8-electrode medical bioelectrical impedance devices

Abstract: Background/Objectives:Bioelectrical impedance analysis (BIA) provides noninvasive measures of skeletal muscle mass (SMM) and visceral adipose tissue (VAT). This study (i) analyzes the impact of conventional wrist-ankle vs segmental technology and standing vs supine position on BIA equations and (ii) compares BIA validation against magnetic resonance imaging (MRI) and dual X-ray absorptiometry (DXA).Subjects/Methods:One hundred and thirty-six healthy Caucasian adults (70 men, 66 women; age 40±12 years) were mea… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

5
139
0
2

Year Published

2018
2018
2021
2021

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 160 publications
(146 citation statements)
references
References 29 publications
5
139
0
2
Order By: Relevance
“…In obesity, a higher hydration of FFM is due to an increased water fraction of FFM in adipose tissue [17]. For obesity, these effects were not adequately accounted for in the original BIA equations [4, 15], since inclusion criteria for the reference population used to generate the BIA algorithm were limited to BMI <35 kg/m 2 [15]. On the other hand, overestimation of FFM by DXA can be explained by an underestimation of trunk FM by fan beam DXA devices [18].…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…In obesity, a higher hydration of FFM is due to an increased water fraction of FFM in adipose tissue [17]. For obesity, these effects were not adequately accounted for in the original BIA equations [4, 15], since inclusion criteria for the reference population used to generate the BIA algorithm were limited to BMI <35 kg/m 2 [15]. On the other hand, overestimation of FFM by DXA can be explained by an underestimation of trunk FM by fan beam DXA devices [18].…”
Section: Discussionmentioning
confidence: 99%
“…kg., Hamburg, Germany) was used for BIA measurements, and a 4C model based on D 2 O dilution, DXA, and ADP was used as reference for FFM, whereas whole-body magnetic resonance imaging (MRI) and sodium bromide (NaBr) dilution were used as references for SMM and ECW, respectively. Details of the study protocol were described previously [4, 15]. In a second phase, 35 obese Caucasian men and women with a BMI ≥30 kg/m 2 were examined using the same study protocol.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations