2017
DOI: 10.3390/ma10030259
|View full text |Cite
|
Sign up to set email alerts
|

Quantification of Wear and Deformation in Different Configurations of Polyethylene Acetabular Cups Using Micro X-ray Computed Tomography

Abstract: Wear is currently quantified as mass loss of the bearing materials measured using gravimetric methods. However, this method does not provide other information, such as volumetric loss or surface deviation. In this work, we validated a technique to quantify polyethylene wear in three different batches of ultrahigh-molecular-polyethylene acetabular cups used for hip implants using nondestructive microcomputed tomography. Three different configurations of polyethylene acetabular cups, previously tested under the … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
17
0

Year Published

2018
2018
2020
2020

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 13 publications
(17 citation statements)
references
References 41 publications
0
17
0
Order By: Relevance
“…[1] shows the results of the THR's wear tests on the simulator taking into account the next main typical normal activities of the patient's daily living: level walking, stair ascending and stair descending, chair sitting and rising, and deep squatting. In the same study, based on the frequency of the cycle of each activity, the relative duration of each type of activity, reduced to the same cycle duration for 1 s, is determined, and is distributed as follows: 44% -level walking, 24% -stair ascending-stair descending, 12% -chair sitting, 12% -chair rising, and 8% -deep squatting.…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…[1] shows the results of the THR's wear tests on the simulator taking into account the next main typical normal activities of the patient's daily living: level walking, stair ascending and stair descending, chair sitting and rising, and deep squatting. In the same study, based on the frequency of the cycle of each activity, the relative duration of each type of activity, reduced to the same cycle duration for 1 s, is determined, and is distributed as follows: 44% -level walking, 24% -stair ascending-stair descending, 12% -chair sitting, 12% -chair rising, and 8% -deep squatting.…”
Section: Methodsmentioning
confidence: 99%
“…In the current study, numerical wear simulation of the THR's spherical polymeric component is conducted, based on the activities indicated in [1] and their duration. At the same time, the wear during the level walking activity is evaluated using parameters regulated by ISO 14242-1.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations