2012
DOI: 10.1016/j.aca.2011.11.018
|View full text |Cite
|
Sign up to set email alerts
|

Quantification of vitamin B6 vitamers in human cerebrospinal fluid by ultra performance liquid chromatography–tandem mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

4
63
1

Year Published

2013
2013
2021
2021

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 64 publications
(68 citation statements)
references
References 29 publications
4
63
1
Order By: Relevance
“…; heater gas of 60 p.s.i., and interface heating temperature of 200°C. MS 2 scans were collected by the third quadrupole operating in resolving quadrupole mode with a scan time of 5 s. Collisioninduced dissociation generated a single fragment ion for each analyte, consistent with previous studies (57) and in agreement with the published values (57). Hence, only one transition was used to quantify each B 6 vitamer (m/z 1693134 for PM; m/z 1723137 for d 3 -PM; m/z 1683150 for PL; m/z 1703134 for pyridoxine, and m/z 2483150 for PLP).…”
Section: Methodsmentioning
confidence: 77%
See 1 more Smart Citation
“…; heater gas of 60 p.s.i., and interface heating temperature of 200°C. MS 2 scans were collected by the third quadrupole operating in resolving quadrupole mode with a scan time of 5 s. Collisioninduced dissociation generated a single fragment ion for each analyte, consistent with previous studies (57) and in agreement with the published values (57). Hence, only one transition was used to quantify each B 6 vitamer (m/z 1693134 for PM; m/z 1723137 for d 3 -PM; m/z 1683150 for PL; m/z 1703134 for pyridoxine, and m/z 2483150 for PLP).…”
Section: Methodsmentioning
confidence: 77%
“…An Ultimate 3000 liquid chromatography system (Dionex) equipped with a Zorbax SB-AQ column (2.1 ϫ 100 mm, 3.5 m, Agilent) with matching guard column (2.1 ϫ 12.5 mm, 5 m) was used for separation. Column temperature was maintained at 25°C, and the injection volume was 20 l. The liquid chromatography gradient was described previously (57). Briefly, initial chromatographic conditions were 99% solvent A (650 mM acetic acid containing 0.01% heptafluorobutyric acid) and 1% solvent B (acetonitrile).…”
Section: Methodsmentioning
confidence: 99%
“…In human cerebrospinal fluid pyridoxal is the dominant B-6 vitamer van der Ham et al 2012;Albersen et al 2014). Median values for pyridoxal and pyridoxal phosphate in the cerebrospinal fluid of infants declined over 50 % between a postmenstrual age of 30-37 and ≥42 weeks .…”
Section: Absorption and Transport Of Vitamin B-6mentioning
confidence: 98%
“…Most separation and detection procedures are reversed-phase high-performance liquid chromatography (HPLC) techniques (Eitenmiller et al 2008) (Ciulu et al 2011;Jin et al 2012;Langer and Lodge 2014), and MS (Hälvin et al 2013;van der Ham et al 2012). Methods using electrochemical detection (ED) have also been proposed but applications to samples other than pharmaceuticals supplements and animal foods are few (Lebiedzińska et al 2007;Marszałł et al 2005).…”
Section: Introductionmentioning
confidence: 99%
“…Pyridoxal-5′-phosphate (PLP), on the other hand, has been reported to be the most biologically active form of vitamin B 6 and functions as a co-factor crucial for numerous enzymatic reactions (di Salvo et al 2012;Eitenmiller et al, 2008;van der Ham et al 2012).…”
Section: Introductionmentioning
confidence: 99%