2003
DOI: 10.1016/s1570-0232(03)00425-2
|View full text |Cite
|
Sign up to set email alerts
|

Quantification of melatonin in human saliva by liquid chromatography–tandem mass spectrometry using stable isotope dilution

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
44
1

Year Published

2004
2004
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 54 publications
(45 citation statements)
references
References 13 publications
0
44
1
Order By: Relevance
“…In these methods, a high concentration of organic solvents, such as 20 -50% of MeOH or MeCN, was required as the mobile phase. [25][26][27]29,30 However, melatonin could not be oxidized in these mobile phases containing a high concentration of organic solvents.…”
Section: Effect Of Organic Solvents On the Oxidation Of Melatonin Andmentioning
confidence: 97%
See 2 more Smart Citations
“…In these methods, a high concentration of organic solvents, such as 20 -50% of MeOH or MeCN, was required as the mobile phase. [25][26][27]29,30 However, melatonin could not be oxidized in these mobile phases containing a high concentration of organic solvents.…”
Section: Effect Of Organic Solvents On the Oxidation Of Melatonin Andmentioning
confidence: 97%
“…Until now, various analytical methods, such as enzyme immunoassay, [18][19][20][21]28 GC-MS [22][23][24] and HPLC methods, [25][26][27]29,30 have been reported for the determination of melatonin. Enzymatic methods (both RIA and ELISA) are frequently used, and various assay kits are commercially available.…”
Section: Development Of a Fully-automated On-line Oxidation Columnswimentioning
confidence: 99%
See 1 more Smart Citation
“…Thus chronomics has a role to play in the initiation and development of various diseases in cultures at different latitudes (melatonin adaption to shift working times in Thai female shift workers [160]), and in industrialized (and developing) countries where lighting and occupational patterns of activity have been/are important health factors. Melatonin has been assayed using deuterated internal standards in high-pressure liquid chromatography tandem mass-spectroscopy [161].…”
Section: B) Melatoninmentioning
confidence: 99%
“…There are many methods reported for quantification of melatonin with different kind of matrix like plasma, saliva, pineal gland and biological samples by GC-MS Chemical ionisation (Fourtillan et al 1994), LC-MS/MS (Eriksson et al 2003;Cao et al 2006), GC-ECD (Greiner and Chan 1978), HPLC-FLD (Rizzo et al 2002;Vitale et al 1996;Iinuma et al 1999;Munoz et al 2009;Lizuka et al 2007;Itoh et al 1997), HPLC-Electrochemical detector (Chanut et al 1998) and HPLC chemiluminesence (Lu et al 2002). Melatonin in human milk was reported by RIA and the method was validated by GC-MS (Illnerova et al 1993).…”
Section: Introductionmentioning
confidence: 99%