2008
DOI: 10.1016/j.jchromb.2008.03.001
|View full text |Cite
|
Sign up to set email alerts
|

Quantification of doripenem in human plasma and peritoneal fluid by high-performance liquid chromatography with ultraviolet detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
44
0

Year Published

2010
2010
2022
2022

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 39 publications
(44 citation statements)
references
References 12 publications
0
44
0
Order By: Relevance
“…[7][8][9][10] Other studies include the quantitation of doripenem in biological fluids. 11,12 For other carbapenems, the works also focus on quantitation by LC, UV spectrophotometry and microbiological assay, applied on stability studies. [13][14][15] For meropenem, Almarsson et al 16 reports the analysis of the drug by proton and 13-carbon NMR coupled with tandem mass spectroscopy, which showed evidence that the structure is stable as CO 2 adduct, in solid state and in solution.…”
Section: Introductionmentioning
confidence: 99%
“…[7][8][9][10] Other studies include the quantitation of doripenem in biological fluids. 11,12 For other carbapenems, the works also focus on quantitation by LC, UV spectrophotometry and microbiological assay, applied on stability studies. [13][14][15] For meropenem, Almarsson et al 16 reports the analysis of the drug by proton and 13-carbon NMR coupled with tandem mass spectroscopy, which showed evidence that the structure is stable as CO 2 adduct, in solid state and in solution.…”
Section: Introductionmentioning
confidence: 99%
“…DRPM Assay Total DRPM concentration in plasma was measured according to the HPLC method described by Ikeda et al 13) with modification. Briefly, 50 µL of 100 µg/mL meropenem in extra pure water (internal standard) and 400 µL of extra pure water were added to 20 µL of plasma in a polyethylene centrifuge tube.…”
Section: Subjectsmentioning
confidence: 99%
“…DP and MP were broad spectrum of antimicrobial activity against both gram-positive and gram-negative bacteria, including pseudomonas aeruginosa [3][4][5].The catalytic effect of citrate, phosphate and acetate buffers on the degradation of imipenem has been studied [6]. Several methods have been reported in the literature for the determination of doripenem and meropenem and its metabolites in biological fluids and pharmaceutical formulation using different techniques, including spectrophotometry, high performance liquid chromatography (HPLC) and liquid chromatography methods [7][8][9][10][11].…”
Section: Introductionmentioning
confidence: 99%