2014
DOI: 10.1016/j.jcis.2013.10.060
|View full text |Cite
|
Sign up to set email alerts
|

Protein immobilization on nanoporous silicon functionalized by RF activated plasma polymerization of Acrylic Acid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
14
0

Year Published

2016
2016
2020
2020

Publication Types

Select...
4
3

Relationship

2
5

Authors

Journals

citations
Cited by 25 publications
(15 citation statements)
references
References 38 publications
1
14
0
Order By: Relevance
“…In the spectra of the pSi‐POct‐PAAc films (Figure (iii)), all of the above‐mentioned peaks were visible. Additionally, a sharp peak at 1722 cm −1 corresponding to the C=O vibrations of the carboxyl group of PAAc was observed . In all the samples with polymer caps, a broad peak centered at 3378 cm −1 was also evident, corresponding to the stretching vibrational mode of hydrogen bonds from absorbed water .…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…In the spectra of the pSi‐POct‐PAAc films (Figure (iii)), all of the above‐mentioned peaks were visible. Additionally, a sharp peak at 1722 cm −1 corresponding to the C=O vibrations of the carboxyl group of PAAc was observed . In all the samples with polymer caps, a broad peak centered at 3378 cm −1 was also evident, corresponding to the stretching vibrational mode of hydrogen bonds from absorbed water .…”
Section: Resultsmentioning
confidence: 99%
“…Additionally,as harp peak at 1722 cm À1 corresponding to the C=Ov ibrations of the carboxyl group of PAAc was observed. [17] In all the samples with polymer caps, ab road peak centered at 3378 cm À1 was also evident, corresponding to the stretching vibrational mode of hydrogen bonds from absorbed water. [16] The adsorptiono f water mostl ikely occurred immediately after the samples were removedf rom the plasma reactor andc ould not be avoided; [18] but this did not affect the performance of the plasma polymer films.…”
Section: Sem Images Inmentioning
confidence: 89%
“…Different precursors and plasma excitation methods, process parameters and reactor geometries influence the plasma polymerization process and lead to a diversity of plasma-chemical reactions and thus to different film properties [58]. The low pressure plasma processes are the most widely used: microwave (2.45 GHz) [59] or capacitively coupled radio frequency (13.56 MHz) [59][60][61][62][63][64][65] activated [60], in planar parallel electrode plates geometry [63][64][65], in steel chamber [59,[63][64][65][66] or glass tubes [62,67,68] reactors, applying a continuous [61,67] or pulsed plasma discharge [59,[63][64][65]69].…”
Section: Organic Coatingsmentioning
confidence: 99%
“…This goal could be achieved through a high degree of cross-linking, but the consequent chains high fragmentation at high discharge power determinates a strong decrease of -COOH groups density. Notwithstanding, it was demonstrated that a finely tuned pulsed RF plasma discharge allows obtaining a high surface density of carboxylic groups (10 15 -10 16 -COOH/cm 2 ), stable in aqueous solutions, able to covalently graft NH 2 terminated c-DNA probes, complementary to Listeria monocytogenes oligonucleotides, for microarray diagnostics [63] and proteins (Protein A) if deposited on porous silicon matrices [64]. Moreover, when applied to polypropylene hernia-repair meshes [65], PPAAc can be successfully loaded with silver nanoparticles that were shown to be moderately released in physiological media.…”
Section: Organic Coatingsmentioning
confidence: 99%
“…In previous works of the authors [4,26,30,31], films with thicknesses included between 80 and 120 nm (processes performed by T Dep between 10 and 20 min) and prepared by means of both continuous wave (CW) and modulated wave (MW) plasma discharge were widely studied. The coating obtained by CW discharge were shown to not retain enough carboxylic functionalities while, among MW coatings, only the film obtained with an RF starting power of 200 W, a duty cycle of 0.1 with a t on of 10 ms and a t off of 90 ms with Ar as carrier gas, were optimal in terms of stability and reproducibility.…”
Section: Plasma Polymerized Acrylic Acidmentioning
confidence: 99%