2008
DOI: 10.2478/s11532-008-0075-7
|View full text |Cite
|
Sign up to set email alerts
|

Properties of naproxen ion-selective electrodes

Abstract: Naproxen membrane electrodes based on different plasticizers and the quaternary ammonium salts (QASs) dimethyldidecylammonium bromide, methyltrioctylammonium chloride, or tetraoctylammonium chloride, were prepared. The following basic parameters were investigated for the optimal electrode: measurement range (10), slope of the linear range of the calibration curve (-58.3 mV decade ), lifetime (2.5 months), dependence of the electrode potential on pH (5.5 -9.0), reproducibility of potential (1.2 mV) and selectiv… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2010
2010
2023
2023

Publication Types

Select...
6
1
1

Relationship

2
6

Authors

Journals

citations
Cited by 12 publications
(15 citation statements)
references
References 13 publications
0
14
0
Order By: Relevance
“…Comparing the results, the best electrodes, containing methyltrioctylammonium chloride (MTOA-Cl) in the membrane, are appropriately plasticized with DBP, NPOE and TEHP (Lenik et al, 2008). For electrodes containing tetraoctylammonium chloride (TOA-Cl) in the membrane, similar potentiometric responses were obtained.…”
Section: Selecting Plasticizers For the Construction Of Ion-selectivementioning
confidence: 51%
“…Comparing the results, the best electrodes, containing methyltrioctylammonium chloride (MTOA-Cl) in the membrane, are appropriately plasticized with DBP, NPOE and TEHP (Lenik et al, 2008). For electrodes containing tetraoctylammonium chloride (TOA-Cl) in the membrane, similar potentiometric responses were obtained.…”
Section: Selecting Plasticizers For the Construction Of Ion-selectivementioning
confidence: 51%
“…On the basis of the literature, there are limited scientific works on the use of ion-selective electrodes for naproxen determination [15][16][17][18]. These electrodes have different constructions: the electrode [15] with liquid membrane type, based on the use of tetraheptylammonium naproxenate, the electrode with polymeric membrane type with methyltrioctylammonium naproxenate [16], the electrode with graphite membrane based on mercury(I) naproxenate [17], and electrodes based on other quaternary ammonium salt in chloride and bromide forms with inner solution of naproxenate in NaCl solution [18].…”
Section: Introductionmentioning
confidence: 99%
“…The description of the electrode construction was presented in earlier papers [39][40][41]. The membrane phase of the electrode consists of two layers placed in a teflon holder.…”
Section: Electrode Construction and Membrane Phase Preparationmentioning
confidence: 99%
“…These were liquid contact electrodes too [50]. Analytical usefulness of the electrodes was tested by performing determinations of 2-(4-isobutylophenyl) propiate acid (ibuprofen) using these ibuprofen electrodes in synthetic samples of Ibuprofen (Sigma), and in pharmaceutical preparations Ibuprofen (Polfa, Pabianice, Poland) and Nurofen Forte Express (Reckitt Benckiser Healthcare International Ltd., Great Britain).…”
Section: *Uv Spectrophotometrymentioning
confidence: 99%