2015
DOI: 10.1016/j.msec.2015.06.050
|View full text |Cite
|
Sign up to set email alerts
|

Preparation of ds-DNA functionalized magnetic nanobaits for screening of bioactive compounds from medicinal plant

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 11 publications
(7 citation statements)
references
References 51 publications
0
6
0
Order By: Relevance
“…In the cyclic voltammetry (CV), the immobilization of nano‐composite on electrodes usually results in a change of current response; therefore, CV has usually been used to characterize the nano‐composite . In this work, the cyclic voltammograms of mCNTs and PD‐mCNTs were measured in phosphate buffer (PBS) (pH 7) containing 0.1 M KCl and 5 mM potassium ferricyanide.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…In the cyclic voltammetry (CV), the immobilization of nano‐composite on electrodes usually results in a change of current response; therefore, CV has usually been used to characterize the nano‐composite . In this work, the cyclic voltammograms of mCNTs and PD‐mCNTs were measured in phosphate buffer (PBS) (pH 7) containing 0.1 M KCl and 5 mM potassium ferricyanide.…”
Section: Resultsmentioning
confidence: 99%
“…Supporting electrolyte: pH 7 PBS containing 5 mM FeCN(K 3 Fe(CN) 6 ) and 0.1 M KCl; scan rate: 50 mV/s. Carbon rings served as the working and counter electrodes, Ag/AgCl reference electrode current response; therefore, CV has usually been used to characterize the nano-composite [40,41]. In this work, the cyclic voltammograms of mCNTs and PD-mCNTs were measured in phosphate buffer (PBS) (pH 7) containing 0.1 M KCl and 5 mM potassium ferricyanide.…”
Section: F I G U R E 3 (A) the Image Of Pd-mcnts (Left) And Mcnts (Rimentioning
confidence: 99%
“…FTIR was used to characterize the surface modification of the MNPs. The electrochemical method could be used for CHO-MNPs and AG-MNPs analysis in which immobilization of the MNPs on the electrode usually resulted in the change of current response [ 26 ]. In this work, by using carbon as a working/counter electrode and Ag/AgCl as a reference electrode for the electrochemical workstation, the cyclic voltammograms (CV) and the differential pulse voltammograms (DPV) of the nano-composites were measured in PBS (10 mM, pH 7.0) containing 5 mM K 3 [Fe(CN) 6 ] and 0.1 M KCl.…”
Section: Methodsmentioning
confidence: 99%
“…Based on our survey, eight works used DNA strands (double, triple, and quadruple) as smart baits to fish out ligands from natural products with anticancer potential. Different approaches were used to apply DNA strands into ligand fishing settings, including dialysis [186], UF [12], MPs [187], and microfluid chips [188,189] as well as other less trivial supports such as streptavidin-coated 96-well plates [49,50] and agarose beads [47]. The DNA-bound ligands were tested in preclinical settings in two specific reports.…”
Section: Monoacylglycerol Lipasementioning
confidence: 99%