Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
2015
DOI: 10.1039/c5ra17047h
|View full text |Cite
|
Sign up to set email alerts
|

Preparation and characterization of a novel tetrakis(4-hydroxyphenyl)porphyrin–graphene oxide nanocomposite and application in an optical sensor and determination of mercury ions

Abstract: Optical chemical sensor for determination of mercury ions.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
30
0
1

Year Published

2016
2016
2023
2023

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 52 publications
(31 citation statements)
references
References 30 publications
0
30
0
1
Order By: Relevance
“…Complexing agents such as EDTA, thiourea and sulfosalcylic acid have a partial reverse effect, and prolonged exposure to them showed no further improvement in reversibility of the optode [38,39]. According to our results, the sensor can be regenerated and reused by exposure to the solution of thiourea (1.0 M) and NaOH (0.1 M).…”
Section: Optode Regenerationmentioning
confidence: 68%
“…Complexing agents such as EDTA, thiourea and sulfosalcylic acid have a partial reverse effect, and prolonged exposure to them showed no further improvement in reversibility of the optode [38,39]. According to our results, the sensor can be regenerated and reused by exposure to the solution of thiourea (1.0 M) and NaOH (0.1 M).…”
Section: Optode Regenerationmentioning
confidence: 68%
“…The development and applications of optical sensors or optodes have grown rapidly and they are applied for determination of various analytes, including cationic, anionic, neutral and gaseous species, because of advantages of easy fabrication, good sensitivity and selectivity, well‐controlled experimental conditions and simple sample preparation . Optodes are used in combination with inexpensive spectrophotometric or spectrofluorometric techniques to provide simple and fast determination methods with low detection limits and good selectivity …”
Section: Introductionmentioning
confidence: 99%
“…However, such groups cannot provide strong interaction with heavy metals as much as nitrogencontaining functional groups [15]. Therefore, in many researches, it is attempted to modify GO with multifunctional molecules such as polymers [15][16][17][18][19], multidentate chelating ligand [20][21][22], to improve adsorption efficiency. Using selective ligand toward metal ions such as pyridine-containing ligand, can be improved capacity and selectivity of adsorbent.…”
Section: Introductionmentioning
confidence: 99%