1997
DOI: 10.1002/9781118592014
|View full text |Cite
|
Sign up to set email alerts
|

Practical HPLC Method Development

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

19
1,128
1
189

Year Published

1998
1998
2011
2011

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 1,358 publications
(1,337 citation statements)
references
References 0 publications
19
1,128
1
189
Order By: Relevance
“…Lijima et al also used this method to isolate an antifungal peptide(AFP) from the hemolymph of a Sarcophaga peregrine (flesh fly) larva (24). It should be noted that, in general, separation of proteins by RP-HPLC would normally denature proteins, but small proteins (< 20,000 Da) can often be separated without significant degradation (27). In this study, the fractions obtained with SPE containing the antifungal activity was further purified by RP-HPLC.…”
Section: Discussionmentioning
confidence: 99%
“…Lijima et al also used this method to isolate an antifungal peptide(AFP) from the hemolymph of a Sarcophaga peregrine (flesh fly) larva (24). It should be noted that, in general, separation of proteins by RP-HPLC would normally denature proteins, but small proteins (< 20,000 Da) can often be separated without significant degradation (27). In this study, the fractions obtained with SPE containing the antifungal activity was further purified by RP-HPLC.…”
Section: Discussionmentioning
confidence: 99%
“…Separation is, in turn, defined by resolution, which is inversely proportional to peak width. 11 To estimate the potential impact of loading on resolution using only a single component, we measured peak width versus load and then plotted the ratio Width min /Width load versus sample load (where Width min is the half-height peak width at lowest load and Width load is the half-height peak width at the measured load). This plot approximates the anticipated falloff 14 in resolution of this compound from a similarly behaving compound as a function of load.…”
Section: Evaluation Of System Loadingmentioning
confidence: 99%
“…Taking into account the baseline resolution (R s >1.5 for bands of similar size [21], only LIC8 column separated 11 PPs to baseline (R s values are in Table 5). Other columns also separated 11 PPs: LC18 and SF (R s = 1.5) for PCP and 24DMP, respectively; SM12 (R s = 1.4) for PCP, and HYP (R s = 1.3) for 4NP, exhibiting the remainder compounds R s A1.…”
Section: Stationary Phase Effectmentioning
confidence: 99%
“…The LC columns widely used are Spherisorb ODS-2 [2, 14 -17] and Hypersil Green [11, 18 -20]. These packings, which are mainly based on Type-A alkyl silica, are less pure and more acidic silica, resulting in an increased silanol ionization as a function of pH, and presumably increased hydrogen-bond acidity [21]. Little attention has been paid to Type-B alkyl silica columns (highly purified, less acidic silica) for PPs separation [22].…”
Section: Introductionmentioning
confidence: 99%