2002
DOI: 10.1021/ac025652f
|View full text |Cite
|
Sign up to set email alerts
|

Potential Application of Gas Chromatography/Tandem Mass Spectrometry in the Measurement of Coeluting Isomers

Abstract: Despite the unprecedented popularity of separation chromatography, the measurement of coeluting isomeric chemicals remains an extremely difficult task. We developed an analytical scheme capable of measuring two coeluting isomers using a single chromatographic column and a gas chromatography/tandem mass spectrometry system. The protocol utilized two product ion fragments generated from a common parent ion associated with the isomers for quantitation. The utility of the analytical scheme was demonstrated with th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...

Citation Types

0
1
0

Year Published

2003
2003
2015
2015

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 9 publications
(1 citation statement)
references
References 7 publications
0
1
0
Order By: Relevance
“…However, GC/MS is preferred now because absolute chromatographic separation for the individual analyte was difficult even if multidimensional GC was employed [10]. Several GC/MS methods have been established based on high-resolution magnetic-sector MS (HR-MS) [11], tandem MS (MS/MS) using an ion trap detector [12][13][14], or triple quadrupole analyzer [15] and time-of-flight MS (TOF-MS) [16], as well as lowresolution quadrupole MS (qMS) [17]. Obviously, HR-MS is the most powerful tool offering high selectivity with satisfactory sensitivity by virtue of its high ultimate resolving power and accurate mass measurement; nevertheless, nowadays only a few laboratories can afford this instrument.…”
mentioning
confidence: 99%
“…However, GC/MS is preferred now because absolute chromatographic separation for the individual analyte was difficult even if multidimensional GC was employed [10]. Several GC/MS methods have been established based on high-resolution magnetic-sector MS (HR-MS) [11], tandem MS (MS/MS) using an ion trap detector [12][13][14], or triple quadrupole analyzer [15] and time-of-flight MS (TOF-MS) [16], as well as lowresolution quadrupole MS (qMS) [17]. Obviously, HR-MS is the most powerful tool offering high selectivity with satisfactory sensitivity by virtue of its high ultimate resolving power and accurate mass measurement; nevertheless, nowadays only a few laboratories can afford this instrument.…”
mentioning
confidence: 99%