2020
DOI: 10.1016/j.snb.2020.127654
|View full text |Cite
|
Sign up to set email alerts
|

Photoelectrochemical determination for acid phosphatase activity based on an electron inhibition strategy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
5
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 18 publications
(6 citation statements)
references
References 59 publications
1
5
0
Order By: Relevance
“…Previous studies on the covalent grafting of diazonium salt on graphitic carbon nitride (g-C 3 N 4 ) have shown a decrease in photocurrent generation with respect to the bare electrode material. , In this study, all the covalently modified electrodes show a much higher photocurrent output compared to the control sample (bare FTO and FTO/SLG), confirming the great potential of the diazonium-derived wires, especially in the case of FTO/SLG electrodes (Figure ). From −100 mV to the anodic region, both metal-based wires show roughly similar photocurrent output.…”
Section: Resultssupporting
confidence: 78%
“…Previous studies on the covalent grafting of diazonium salt on graphitic carbon nitride (g-C 3 N 4 ) have shown a decrease in photocurrent generation with respect to the bare electrode material. , In this study, all the covalently modified electrodes show a much higher photocurrent output compared to the control sample (bare FTO and FTO/SLG), confirming the great potential of the diazonium-derived wires, especially in the case of FTO/SLG electrodes (Figure ). From −100 mV to the anodic region, both metal-based wires show roughly similar photocurrent output.…”
Section: Resultssupporting
confidence: 78%
“…Compared to other detection methods (Table S1 in ESM), the method is competitive to detect ACP as low as 0.04 mU/mL (372 nm) and 0.38 mU/mL (614 nm) (signal/noise = 3) [38], and the linear ranges are 0.13-5.00 mU/mL and 1.25-20.00 mU/mL, respectively, lower than that reported with C-QDs [39] and with proton nuclear magnetic resonance [40]. Although the detection limit is higher than electrochemistry assay [41], the proposed method is more feasible without tedious preparation. Compared to the fluorescence assay based on N-CDs [42], the proposed method exhibits a shorter hydrolysis time.…”
Section: Application Of Acp Assaymentioning
confidence: 67%
“…Huang et al. developed a novel PEC sensor‐based platform for determining acid phosphatase (ACP), [ 117 ] which is a common hydrolase in human tissues and fluids and catalyzes the hydrolysis of phosphate monoesters, which plays a critical role in several important processes. [ 118 ] Abnormal expression of ACP in the body is a vital indicator of many diseases, such as prostate cancer, Gaucher's disease, hyperparathyroidism, multiple myeloma.…”
Section: Applications Of G‐c3n4 In Signal‐transducing Agent For Sensomentioning
confidence: 99%
“…Huang and co‐workers have developed a TNA/g‐C 3 N 4 /3,5‐diamino‐1,2,4‐triazole (DAT) sensor to utilize the electron inhibition performance of DAT and the coordination of Fe(II) with DAT (Figure 9A). [ 117 ] This work involved electrochemically grafting DAT diazonium salt onto the surface of the TNA/g‐C 3 N 4. The results were that the PEC signal response decreased significantly because of the electron hindrance effect of the DAT films.…”
Section: Applications Of G‐c3n4 In Signal‐transducing Agent For Sensomentioning
confidence: 99%
See 1 more Smart Citation