2002
DOI: 10.1063/1.1423782
|View full text |Cite
|
Sign up to set email alerts
|

Performance of a grating monochromator at BL27SU beamline of SPring-8 in the higher energy region

Abstract: Performance tests were carried out on a varied line-spacing plane grating monochromator at BL27SU of SPring-8 in the higher energy region using photoabsorption spectra of gas and solid samples and photoelectron spectra of Xe 5p 3/2 . A flux of 1ϫ10 11 photons/s/100 mA/0.02% b.w. was achieved at 2 keV. The photon flux steeply decreased above 2 keV to 5ϫ10 9 photons/s/100 mA/0.02% b.w. at 2.8 keV.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
24
0

Year Published

2004
2004
2024
2024

Publication Types

Select...
10

Relationship

2
8

Authors

Journals

citations
Cited by 59 publications
(24 citation statements)
references
References 13 publications
0
24
0
Order By: Relevance
“…The radiation source is a figure-8 undulator, whose emitted radiation is linearly polarized either in the horizontal plane of the storage ring (first order) or in the vertical plane perpendicular to it (0.5th order) [12]. The Hettrick-type monochromator of this beamline can provide soft x rays in the range 150 eV to 2.5 keV, with very narrow photon bandwidth at a resolution up to 14 000 [13,14]. The electron spectroscopy apparatus consists of a hemispherical electron analyzer (Gammadata-Scienta SES-2002), a gas cell, and a differentially pumped chamber [15].…”
Section: Methodsmentioning
confidence: 99%
“…The radiation source is a figure-8 undulator, whose emitted radiation is linearly polarized either in the horizontal plane of the storage ring (first order) or in the vertical plane perpendicular to it (0.5th order) [12]. The Hettrick-type monochromator of this beamline can provide soft x rays in the range 150 eV to 2.5 keV, with very narrow photon bandwidth at a resolution up to 14 000 [13,14]. The electron spectroscopy apparatus consists of a hemispherical electron analyzer (Gammadata-Scienta SES-2002), a gas cell, and a differentially pumped chamber [15].…”
Section: Methodsmentioning
confidence: 99%
“…The present experiment has been carried out on the c branch of the high-resolution photochemistry beamline 27SU [20][21][22] at SPring-8, the 8 GeV synchrotron radiation facility in Japan. The radiation source is a figure-8 undulator [23].…”
mentioning
confidence: 99%
“…Small-angle scattering measurements were performed at beamline 11A of the Photon Factory, KEK, and beamline 27SU of SPring8, Japan, using a set of gratings and curved mirrors (Ohashi et al, 2001;Tamenori et al, 2002, Kitajima, 2015. Measurements were made with a CCD detector provided by Hamamatsu Photonics Co. Ltd. A back-illuminated cooled CCD coupled with tapered fiber optics, with a P43 phosphor plate for use in the tender X-ray region, was adopted.…”
Section: Resultsmentioning