2014
DOI: 10.1016/j.proenv.2014.03.016
|View full text |Cite
|
Sign up to set email alerts
|

Performance-based Fire Safety Evacuation in High-rise Building Flats in Indonesia – A Case Study in Bandung

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
13
0
1

Year Published

2016
2016
2024
2024

Publication Types

Select...
4
4
1

Relationship

0
9

Authors

Journals

citations
Cited by 22 publications
(14 citation statements)
references
References 4 publications
0
13
0
1
Order By: Relevance
“…PBD has been implemented in building architectural design to aid emergency evacuation. Various applications in this area [82][83][84][85][86][87][88][89] are summarized in Table A6. The building evacuation model is one of the important tasks to be designed to assess the level of life safety when a disaster, such as fire or earthquake, happens.…”
Section: Building Architectural Design For Evacuationmentioning
confidence: 99%
See 1 more Smart Citation
“…PBD has been implemented in building architectural design to aid emergency evacuation. Various applications in this area [82][83][84][85][86][87][88][89] are summarized in Table A6. The building evacuation model is one of the important tasks to be designed to assess the level of life safety when a disaster, such as fire or earthquake, happens.…”
Section: Building Architectural Design For Evacuationmentioning
confidence: 99%
“…With 410 s RSET and 500 s ASET, the design is affirmed to meet evacuation performance. Sujatmiko et al [88] performed a similar study for a 21-floor building located in Indonesia. They compared the travel time of evacuation experiment using trained and non-trained occupants, and that generated from FDS-EVAC simulation.…”
Section: Building Architectural Design For Evacuationmentioning
confidence: 99%
“…Building designs in each country are differences. Some countries use prescriptive codes, but others use performance based designs for evacuation [2,4,[7][8][9][10][11].…”
Section: Literature Reviewmentioning
confidence: 99%
“…35 The standard of Critical Radiant Flux (CRF), 2.5 kW/m 2 , which is often hard to measure in the designing process, and most scholars apply it indirectly with the corresponding smoke layer temperature(about 180°C). 36,37 Higher Education Mega Center North, a popular metro station in the higher education mega center of Guangzhou, sitting in an isolated island, which is a typical side platform station, is taken as the example to investigate in this work as it is the main entrance for students to enter the island. The station serves more than 10 colleges and universities; without clear and practical emergency plans, the lives of people in such a crowded station would be under threat.…”
Section: Introductionmentioning
confidence: 99%