Abstract: Background: Mitral para-prosthetic leaks are rare but major complications of mitral heart valve replacements. When they must be re-operated, they are burdened with high mortality rates. We proposed to review our surgical experience in terms of approach and type of operation carried out.Methods: Demographic, preoperative, intraoperative and postoperative characteristics of 34 patients benefited from a surgical treatment of mitral paravalvular leak, at the Brugmann University Hospital between 1996 and 2016, have… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
2
0
2

Year Published

2019
2019
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 25 publications
1
2
0
2
Order By: Relevance
“…Although incidence of PVL was higher among patients with non-pledgeted technique (6.1%) than in the pledgeted technique group (1.96%), it was statistically insignificant. This is comparable to results showed by Kim et al (12) and Dziubek et al (16).…”
Section: Discussionsupporting
confidence: 92%
“…Although incidence of PVL was higher among patients with non-pledgeted technique (6.1%) than in the pledgeted technique group (1.96%), it was statistically insignificant. This is comparable to results showed by Kim et al (12) and Dziubek et al (16).…”
Section: Discussionsupporting
confidence: 92%
“…Due to the high mortality associated with surgical PVL closure, transcatheter PVL closure emerged as a safe and effective procedure. Today, the operator has the opportunity of using multiple devices concurrently, achieving outstanding results, and eliminating this common and serious complication (102)(103)(104)(105)(106).…”
Section: Hemolysis and Paravalvular Leakmentioning
confidence: 99%
“…Наряду с этим репротезирование клапана стандартным путем при полном удалении не функционирующего БП может создать предпосылки для формирования парапротезных фистул из-за геометрического несоответствия склеротически измененного, кальцифицированного и вследствие этого деформированного нативного фиброзного кольца и манжеты имплантируемого устройства. В свою очередь по литературным данным 1-2% парапротезных фистул требуют повторного вмешательства, летальность при котором может достигать от 3,7 до 22% [32].…”
Section: опыт применения технологии "Valve-on-valvе"unclassified
“…В продолжение настоящей темы следует отметить, что по литературным данным средние сроки наблюдения технологии "valve-on-valve" в отдаленном периоде не превысили 60-98 мес. [33,35] и в большей части публикаций были не более 1-3 лет [21][22][23][24][25][26][27][28][29][30][31][32][33][34], а также малое количество наблюдений (n=100) -всё это на сегодняшний день не позволяет получить всеобъемлющее представление о выживаемости и отсутствии нелетальных осложнений у данной категории реципиентов преимущественно МП. Также пока ещё отсутствуют предпосылки получить ответ на вопрос: "Как будет развиваться дисфункция БП, имплантированного в каркас другого клапана?".…”
Section: заключениеunclassified