2010
DOI: 10.1002/anie.200906314
|View full text |Cite
|
Sign up to set email alerts
|

Paper Spray for Direct Analysis of Complex Mixtures Using Mass Spectrometry

Abstract: Complex mixtures can be ionized directly from paper for quantitative mass spectrometric analysis of trace components. Prior separations are an option.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
259
0
2

Year Published

2011
2011
2021
2021

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 644 publications
(261 citation statements)
references
References 21 publications
0
259
0
2
Order By: Relevance
“…It is likely that such suppression will occur, however, at very low concentrations of drug where the internal standard is several orders of magnitude more concentrated. Further experiments are needed to determine the linear dynamic range, although previous studies with paper spray indicate that the method is linear over at least three decades [5].…”
Section: Ionization Suppressionmentioning
confidence: 98%
See 2 more Smart Citations
“…It is likely that such suppression will occur, however, at very low concentrations of drug where the internal standard is several orders of magnitude more concentrated. Further experiments are needed to determine the linear dynamic range, although previous studies with paper spray indicate that the method is linear over at least three decades [5].…”
Section: Ionization Suppressionmentioning
confidence: 98%
“…The chemotherapeutic drug imatinib, for example, was detected as low as 50 ng/mL from dried blood, well below the typical therapeutic value for this drug [18], and the analysis showed good linearity over the entire range examined (62.5 ng/mL to 4 g/mL) [5]. The paper spray method is also simple (it involves a single step), it can be performed on less than a microliter of blood, requires small amounts of organic solvent, and uses low cost and readily available materials.…”
Section: Introductionmentioning
confidence: 94%
See 1 more Smart Citation
“…Analytes of interest can be investigated through a myriad of sampling strategies, such as deposition via pipetting, swabbing or dipping, and the swab itself can be used as a surface-transfer medium to investigate bound, trace residues [6,19]. Addition of a small aliquot (1-2 µL) of solution (e.g., 1:1 MeOH:H 2 O with 0.1% formic acid via pipette) and high voltage allows analyte dissolvation and wicking/elution to the triangular egress of the paper, from which an ESI-like spray is generated [48]. As there is no need for pneumatics or extensive sample preparation, it is one of the simplest techniques for coupling to portable MS systems.…”
Section: Paper Spray Ionization (Psi)mentioning
confidence: 99%
“…First, following standard FTA extraction protocol, we plan to apply preconcentrated samples for FTA R cards. Second, we could analyze the preconcentrated sample reservoir using paper-based mass spectrometry [26,27].…”
Section: Isolation and Extraction Of Preconcentration Plug With Foldimentioning
confidence: 99%