2012
DOI: 10.1166/jbn.2012.1391
|View full text |Cite
|
Sign up to set email alerts
|

Osteoblast Activity on Anodized Titania Nanotubes: Effect of Simulated Body Fluid Soaking Time

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

7
17
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
6
3

Relationship

3
6

Authors

Journals

citations
Cited by 31 publications
(24 citation statements)
references
References 46 publications
7
17
0
Order By: Relevance
“…The best biological answer was visible for nanotubes obtained at 5 V, whose diameters were ~20 nm [136]. This result is in accordance with earlier reports [127][128][129][130][131][132][133][134], however, our investigations revealed that the annealing of amorphous samples was not so indispensable [136].…”
Section: Titania Nanotubes (Tnts)supporting
confidence: 92%
See 1 more Smart Citation
“…The best biological answer was visible for nanotubes obtained at 5 V, whose diameters were ~20 nm [136]. This result is in accordance with earlier reports [127][128][129][130][131][132][133][134], however, our investigations revealed that the annealing of amorphous samples was not so indispensable [136].…”
Section: Titania Nanotubes (Tnts)supporting
confidence: 92%
“…Diameters of 15-20 nm are optimal and in case of such TNT presence on the surface of titanium implants, increase in adhesion and proliferation of several types of living cells, such as fibroblasts, osteoblasts, osteoclasts, mesenchymal stem cells, hematopoietic stem cells, and endothelial cells, was confirmed [127][128][129][130][131][132][133][134]. Higher tube diameters (>100 nm) have no positive influence on the increasing of adhesion or proliferation and some authors have shown that TNT of such diameters led to apoptosis, i.e., programmed cell death [135].…”
Section: Titania Nanotubes (Tnts)mentioning
confidence: 86%
“…41 Previous studies showed that surface wettability and roughness were crucially important for cellular responses to the substrates. [42][43][44] In the present study, we show that the water contact angle was signicantly decreased by the HA coating on the Ti 6 Al 4 V scaffold ( Fig. 1C(d)), indicating that the surface wettability and hydrophilicity was substantially enhanced.…”
Section: Discussionsupporting
confidence: 55%
“…After etching, plates were washed with deionized water and air-dried at 70°C inside a vacuum oven. 44…”
Section: Titanium Platesmentioning
confidence: 99%