2022
DOI: 10.1002/mp.15874
|View full text |Cite
|
Sign up to set email alerts
|

Optimized acoustic streaming generated at oblique incident angles to improve ultrasound thrombolysis effect

Abstract: Background: Combined with thrombolytic drugs and/or microbubbles, ultrasound (US) has been regarded as a useful tool for thrombolysis treatment by taking its advantages of noninvasive, non-ionization, low cost, and accurate targeting of tissues deep in body. Recently, low-intensity pulsed US, which can cause fewer complications by stable cavitation and acoustic streaming other than more violent effects, has attracted broad attention. Purpose: However, the thrombolysis effect in practice might not achieve expec… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
2
1

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(5 citation statements)
references
References 96 publications
(194 reference statements)
0
5
0
Order By: Relevance
“…Due to its potential to improve the drug efficiency and soften the surface of thrombus [15] , [44] , cavitation activity, especially the violent IC activity, is expected to become more controllable element in thrombolytic therapy to guarantee both clinical efficacy and safety. Fig.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…Due to its potential to improve the drug efficiency and soften the surface of thrombus [15] , [44] , cavitation activity, especially the violent IC activity, is expected to become more controllable element in thrombolytic therapy to guarantee both clinical efficacy and safety. Fig.…”
Section: Resultsmentioning
confidence: 99%
“…The calcium chloride solution (Yuanye Bio-Technology Co., Ltd, China), bovine whole blood (Beibo Biology Inc., China) and bovine thrombin (MP Biomedicals Co., Ltd, USA) were used to prepare the thrombus. Urokinase (Macklin Biochemical Co., Ltd, China) was initiated by bovine plasma (Yuanye Bio-Technology Co., Ltd, China) [44] .…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Each experimental group was repeated three times, resulting in a total of 18 valid clot samples used for analysis. The clot weight was measured before and after ultrasound treatment for further assessment [44], and the lysis ratio L was calculated by:…”
Section: In Vitro Experimentsmentioning
confidence: 99%