Optimization on fresh outdoor air ratio of air conditioning system with stratum ventilation for both targeted indoor air quality and maximal energy saving

Abstract: Fo r m o r e info r m a tio n, in cl u di n g o u r p olicy a n d s u b mi s sio n p r o c e d u r e , pl e a s e c o n t a c t t h e R e p o si to ry Te a m a t: u si r@ s alfo r d. a c. u k .Please cite this article as: Cheng Y, Zhang S, Huan C, Oladokun MO, Lin Z, Optimization on fresh outdoor air ratio of air conditioning system with stratum ventilation for both targeted indoor air quality and maximal energy saving, Building and Environment (2018), doi: https://doi. AbstractStratum ventilation can energy e… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
45
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 103 publications
(46 citation statements)
references
References 80 publications
1
45
0
Order By: Relevance
“…The thermal preferences of Subzones A, B, C and D are randomly produced [47] to be 0.23, -0.70, 0.52 and 0.65 respectively within ±0.75 (i.e., ω =0. 23, ω =-0.70, ω N =0.52, ω O =0.65 in Figure 3), which is consistent with Wang et al [21]. Thus, the conventional method controls the averaged thermal condition of the occupied zone as close to 0.18 (i.e., the averaged thermal preference of the subzones) as possible.…”
Section: Accepted Manuscriptsupporting
confidence: 86%
See 2 more Smart Citations
“…The thermal preferences of Subzones A, B, C and D are randomly produced [47] to be 0.23, -0.70, 0.52 and 0.65 respectively within ±0.75 (i.e., ω =0. 23, ω =-0.70, ω N =0.52, ω O =0.65 in Figure 3), which is consistent with Wang et al [21]. Thus, the conventional method controls the averaged thermal condition of the occupied zone as close to 0.18 (i.e., the averaged thermal preference of the subzones) as possible.…”
Section: Accepted Manuscriptsupporting
confidence: 86%
“…Although the thermal condition of each subzone can be directly measured, the measurements would increase the cost of the sensors in operation [17]. Moreover, the sensors might disturb the space usage and the occupants could affect the accuracy of the sensors [23]. These [30].…”
Section: Proposed Subzone Control Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Since the CO 2 concentration is a good indicator of indoor air pollution in occupied spaces [37,44,60], it was used to evaluate the indoor air quality in the studied building. Following the ASHRAE 62.1 standard [48], the CO 2 generation rate was a function of the physical activity level of the occupants.…”
Section: Numerical Model Of Building Thermal Beahviourmentioning
confidence: 99%
“…The selected tool to its implementation was MATLAB Simulink (version R2017a, The MathWorks, Inc, Natick, MA, USA), due to its wide use in research and multiple available possibilities, and TRNSYS (version 17, Thermal Energy System Specialists, LLC, Madison, WI, USA) for the thermal modelling. TRNSYS is also used for research purposes when modelling buildings and HVAC systems, as in [39].…”
Section: Simulation Modelmentioning
confidence: 99%