Optimization of micro‐HPLC peak focusing for the detection and quantification of low hepcidin concentrations

Abstract: Micro-high-performance liquid chromatography is a miniaturized, economic and ecological chromatographic system allowing the use of reduced size chromatographic columns. Coupled with electrospray ionization tandem mass spectrometry, this technique can be used to detect and quantify low concentrations of peptides. In this study, hepcidin was used as the model compound and analysed using octadecylsilica stationary phase by means of a gradient elution mode at a flow rate of 4 μL/min. Several parameters were studie… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
5
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 23 publications
0
5
0
Order By: Relevance
“…This graphic also presents XIC chromatograms obtained by HPLC at a flow rate of 400 μL per minute. Better results, in terms of sensitivity, compared with classical HPLC, have already been reported in other applications. , Since the Guidance document SANCO/12571/2013 also recommends LC-MS performance requirements, a mixture of pesticides and internal standards was used to assess the stability and repeatability of retention times and peak areas. Mixtures containing 90 pesticides in a solvent and in the selected matrices (within a 5 μg kg –1 to 400 μg kg –1 concentration range) were analyzed over 3 days to assess the stability of chromatographic conditions, and thus the repeatability of retention times.…”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…This graphic also presents XIC chromatograms obtained by HPLC at a flow rate of 400 μL per minute. Better results, in terms of sensitivity, compared with classical HPLC, have already been reported in other applications. , Since the Guidance document SANCO/12571/2013 also recommends LC-MS performance requirements, a mixture of pesticides and internal standards was used to assess the stability and repeatability of retention times and peak areas. Mixtures containing 90 pesticides in a solvent and in the selected matrices (within a 5 μg kg –1 to 400 μg kg –1 concentration range) were analyzed over 3 days to assess the stability of chromatographic conditions, and thus the repeatability of retention times.…”
Section: Resultsmentioning
confidence: 99%
“…23, 26 Since Guidance document 275 SANCO/12571/2013 24 also recommends LC-MS performance requirements, a mixture of pesticides 276…”