Pharmaceutical counterfeiting is a permanently growing problem. Control laboratories are constantly analysing counterfeit medicines. In industrialised countries, one of the main counterfeited class of medicines are erectile dysfunction drugs. This paper describes the development and validation of a fast method to detect and quantify the three authorised phosphodiesterase type 5 inhibitors and five analogues. The method is based on the use of a sub-2 microns polar-embedded column with a gradient using acetonitrile as organic modifier and 10 mM ammonium formate buffer (pH 3.5) as aqueous component of the mobile phase.The separation was achieved in less than 4.5 min. The method has also been compared to the registered HPLC method for the assay of Viagra ® which was considered as the reference method.The method is also compatible with on-line coupling mass spectrometry and will significantly reduce analysis times and solvent consumption.
Micro-high-performance liquid chromatography is a miniaturized, economic and ecological chromatographic system allowing the use of reduced size chromatographic columns. Coupled with electrospray ionization tandem mass spectrometry, this technique can be used to detect and quantify low concentrations of peptides. In this study, hepcidin was used as the model compound and analysed using octadecylsilica stationary phase by means of a gradient elution mode at a flow rate of 4 μL/min. Several parameters were studied to optimize peak focusing. Using the methodology of experimental design, the mobile-phase gradient conditions and the sample composition were optimized in order to maximize the sensitivity and minimize retention time. Stability of the target peptide in solution was also demonstrated.
A method for the resolution of a peptides mixture including hepcidin-25, an iron metabolism marker, was developed by CE-ESI-MS. Several strategies were tested to optimize peptide separation, such as the addition of cyclodextrins or organic solvents in the BGE or the use of coated capillaries. Best results in terms of resolution, symmetry and efficiency were obtained with a BGE made of 500 mM ammonium acetate pH 4.5/ACN 70:30 v/v. Using the methodology of experimental design, BGE concentration, sheath liquid composition and MS-coupling parameters were then optimized in order to obtain the best signal intensity for hepcidin. Finally, a 225 mM BGE and a sheath liquid composed of isopropanol/water 80:20 v/v containing 0.5% v/v formic acid were selected as it constitutes the best compromise for selectivity, peak shape and sensitivity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.