2018
DOI: 10.1080/00405000.2018.1531742
|View full text |Cite
|
Sign up to set email alerts
|

Optimization of material and process parameters of fibrous quilt for comfortable heat loss from human body

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2019
2019
2025
2025

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 11 publications
(7 citation statements)
references
References 25 publications
0
7
0
Order By: Relevance
“…where R -air permeability, dm 3 /(m 2 Ás); q v -average air flow, dm 3 /min (l/min); S Btested area, cm 2 ; 167 -coefficient for calculation from dm 3 /(cm 2 Ámin) to dm 3 /(m 2 Ás).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…where R -air permeability, dm 3 /(m 2 Ás); q v -average air flow, dm 3 /min (l/min); S Btested area, cm 2 ; 167 -coefficient for calculation from dm 3 /(cm 2 Ámin) to dm 3 /(m 2 Ás).…”
Section: Methodsmentioning
confidence: 99%
“…In case the rate of heat loss from body is higher than the metabolic heat generation, body feels discomfort. Maintenance of the comfortable heat loss from the human body is a primary function of the winter clothing [3,4]. The basic heat transfer mechanisms, such as conduction, convection and radiation, are very well known.…”
Section: Introductionmentioning
confidence: 99%
“…The thermal conductivity of the PE film and the woven fabrics was measured as Alamdita tester in terms of W m -1 K -1 . Conduction methods and some extent of heat transfer may occur due to vapors convection and radiative heat transfer [29]. The thermal conductivity of all the fabrics samples was measured, with three readings taken for each sample.…”
Section: Measurement Of Thermal Conductivitymentioning
confidence: 99%
“…Th e thermal conductivity of the samples was measured using a thermal conductivity tester fabricated ( Figure 1) by the Department of Textile Technology, NIT Jalandhar, India [17]. Th e instrument was fabricated according to the guidelines of the ASTM C518-10 standard for the measurement of the thermal conductivity of high-loft thick fi brous material, where the simulated measurement conditions were exactly the same as application conditions.…”
Section: Measurement Of Thermal Conductivitymentioning
confidence: 99%
“…Th e result is the better thermal resistance of polyester nonwoven fabric compared with nettle fibre nonwoven fabric. Th e thermal resistance of a nonwoven structure is infl uenced by its structural compactness with optimum porosity [17]. A good…”
Section: Thermal Conductivity Of Nonwoven Fabricsmentioning
confidence: 99%