Optimization of culture conditions for biological hydrogen production by Citrobacter freundii CWBI952 in batch, sequenced-batch and semicontinuous operating mode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
21
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
7
2

Relationship

4
5

Authors

Journals

citations
Cited by 38 publications
(22 citation statements)
references
References 46 publications
1
21
0
Order By: Relevance
“…The HPLC analysis was carried out using an Agilent 1110 series (HP Chemstation software) with a Supelcogel C-610H column preceded by a Supelguard H pre-column (oven temperature 40°C), 0.1 % H 3 PO 4 (in milliQ water) as the isocratic mobile phase at a flow rate of 0.5 ml.min _1 and a differential refraction index detector (RID, heated at 35°C). The process lasted for 35 min at a maximum pressure of 60 bars as described formerly (Hamilton et al 2010).…”
Section: Methodsmentioning
confidence: 99%
“…The HPLC analysis was carried out using an Agilent 1110 series (HP Chemstation software) with a Supelcogel C-610H column preceded by a Supelguard H pre-column (oven temperature 40°C), 0.1 % H 3 PO 4 (in milliQ water) as the isocratic mobile phase at a flow rate of 0.5 ml.min _1 and a differential refraction index detector (RID, heated at 35°C). The process lasted for 35 min at a maximum pressure of 60 bars as described formerly (Hamilton et al 2010).…”
Section: Methodsmentioning
confidence: 99%
“…on-column injections of 50 µL gas samples on CarboPLOT P7 column (Varian Chrompack, NL) in a gas chromatography system (HP8950 SeriesII) equipped with a TCD detector, using either nitrogen or helium as carrier gas (respectively for hydrogen and for nitrogen/methane/carbon dioxide detection). A detailed procedure can be found elsewhere [37].…”
Section: Hydrogen Production Measurementmentioning
confidence: 99%
“…Gas chromatography and high performance liquid chromatography analysis H 2 , CH 4 , and CO 2 were determined using a method described by Hamilton et al (2010), and separation was achieved using a Hewlett Packard 5890 Series II gas chromatograph (GC; Agilent Technologies, Santa Clara, CA, USA) equipped with a 30 m long, 0.32 mm id Alltech GAS PRO GSC column (Grace, Deerfield, IL, USA) in series with a 20 m long, 0.25 mm id…”
Section: Koh Operating Proceduresmentioning
confidence: 99%