1999
DOI: 10.1088/0031-9155/44/10/312
|View full text |Cite
|
Sign up to set email alerts
|

Optimal photon energies for IUdR K-edge radiosensitization with filtered x-ray and radioisotope sources

Abstract: The purpose of this work is to determine the most physically effective radiation energy for K-edge absorption of x- or gamma-rays by iododeoxyuridine (IUdR) on Chinese hamster ovary (CHO) cells. Brachytherapy sources (Sm-145, I-125, Yb-169 and Am-241) and x-ray beams (30 kVp, 100 kVp and 100 kVp with gold, gadolinium, lead or tungsten filtration) were investigated for their preferential absorption qualities by IUdR sensitized DNA. The 30 kVp, 100 kVp and 100 kVp with tungsten filtration were then used to irrad… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

4
48
0
4

Year Published

2001
2001
2020
2020

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 38 publications
(56 citation statements)
references
References 18 publications
4
48
0
4
Order By: Relevance
“…Consequently, our experimental results are in good agreement with the calculations made by Karnas et al (1999). Due to the lack of available synchrotron sources, adjustable monochromatic beams were not used to validate their calculation, but CHO cells exposed to 10 mM IUdR for 3 days and irradiated with medium energy X-ray tube (100 kV p ) exhibited SER 1% of 1.8 vs 1.4 for lowenergy spectrum (30 kV p ).…”
Section: Iodine Contrast Agent As Radiation Sensitisersupporting
confidence: 82%
See 3 more Smart Citations
“…Consequently, our experimental results are in good agreement with the calculations made by Karnas et al (1999). Due to the lack of available synchrotron sources, adjustable monochromatic beams were not used to validate their calculation, but CHO cells exposed to 10 mM IUdR for 3 days and irradiated with medium energy X-ray tube (100 kV p ) exhibited SER 1% of 1.8 vs 1.4 for lowenergy spectrum (30 kV p ).…”
Section: Iodine Contrast Agent As Radiation Sensitisersupporting
confidence: 82%
“…Therefore, two different concepts were to be considered: the first one based on the occurrence of particular events; the second one taking into account the difference in absorption capacity of the living matter with and without the presence of a certain concentration of iodine, whatever the structure imbedding it. As pointed out by Karnas et al (1999) and Solberg et al (1992b), monochromatic X-rays produced by a synchrotron should be the best tool for verifying these hypotheses. Powerful third generation synchrotrons are now available to deliver broad X-ray beams (10 -100 keV), brilliant enough for using monochromators and able to precisely select the desired X-rays energy.…”
mentioning
confidence: 89%
See 2 more Smart Citations
“…Получение монохроматических пучков фотонов сопряжено со значительными техническими трудностями, поýтому S.J. Karnas et al [24] пытались использовать облучение клеток китайского хомячка в присутствии IUdR фотона-ми обычных рентгеновских установок, варьируя фильтры и напряжение на трубке. Эксперименты подтвердили ýффективность ýтой технологии.…”
Section: фотон-захватная терапияunclassified