Open-Circuit Fault Control Techniques for Bearingless Multisector Permanent Magnet Synchronous Machines

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
10
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(10 citation statements)
references
References 20 publications
0
10
0
Order By: Relevance
“…As shown in Table 2, SB fault-detection methods have been widely carried out using vector space decomposition (VSD) components [15,18,44,[53][54][55][56][57][58][59][60][61][62][71][72][73][74][75], although monitoring just the phase currents has also been suggested for this purpose [48][49][50][51][52][67][68][69][70], especially in older papers. In a 2012 publication [48], Meinguet et al propose the localization of open-phase faults by quantifying the imbalance of the phase currents, exploiting the fact that these signals are more affected by the occurrence of a fault than the main (α 1 -β 1 ) VSD subspace.…”
Section: Sb Detection Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…As shown in Table 2, SB fault-detection methods have been widely carried out using vector space decomposition (VSD) components [15,18,44,[53][54][55][56][57][58][59][60][61][62][71][72][73][74][75], although monitoring just the phase currents has also been suggested for this purpose [48][49][50][51][52][67][68][69][70], especially in older papers. In a 2012 publication [48], Meinguet et al propose the localization of open-phase faults by quantifying the imbalance of the phase currents, exploiting the fact that these signals are more affected by the occurrence of a fault than the main (α 1 -β 1 ) VSD subspace.…”
Section: Sb Detection Methodsmentioning
confidence: 99%
“…However, R2 is not fulfilled either. Although phase currents can exhibit these limitations when monitored, Wen et al recently proposed in [52] a fault-detection method based on them for identifying the sector affected by an OC fault, in a three-sector nine-phase PMSM. The alarm is set when the instantaneous (not average) absolute value of a phase current is lower than a threshold while the current error of said phase (with respect to its control reference) is large.…”
Section: Sb Detection Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Since the main objective of this paper is to investigate the postfault reconfiguration and the associated control for the APGC, regarding the fault detection, this paper did not propose a new method. The open-circuit fault detection method proposed in [32] is adopted because it is simple for implementation, fast and accurate for detection, and needless for extra sensors.…”
Section: Fault Detectionmentioning
confidence: 99%