On multichannel film dosimetry with channel-independent perturbations

Abstract: Purpose: Different multichannel methods for film dosimetry have been proposed in the literature. Two of them are the weighted mean method and the method put forth by Micke et al and Mayer et al. The purpose of this work was to compare their results and to develop a generalized channel-independent perturbations framework in which both methods enter as special cases. Methods: Four models of channel-independent perturbations were compared: weighted mean, Micke-Mayer method, uniform distribution and truncated norm… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
58
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 45 publications
(58 citation statements)
references
References 32 publications
0
58
0
Order By: Relevance
“…Images were acquired in 48-bit RGB mode using 72 dpi resolution with the image-processing options turned off. The doses were obtained using the Radiochromic.com (http://radiochromic.com/) web application [10], v1.1 through v2.5.…”
Section: Methodsmentioning
confidence: 99%
“…Images were acquired in 48-bit RGB mode using 72 dpi resolution with the image-processing options turned off. The doses were obtained using the Radiochromic.com (http://radiochromic.com/) web application [10], v1.1 through v2.5.…”
Section: Methodsmentioning
confidence: 99%
“…This latter advance has made it possible to correct response values for the effects of nonuniformity in the thickness of the active layer in the films. [20][21][22][23][24] Nevertheless, it is well recognized that several of the properties of radiochromic film require special attention in measuring the film response on a CCD-based document scanners. These include film orientation on the scanner, 25 postexposure changes, [26][27][28] as well as the lateral response artifact.…”
Section: Introductionmentioning
confidence: 99%
“…However, care must be taken to reduce uncertainties associated with film dosimetry including film batch and scan orientation consistency, postexposure time, scanner warm‐up characteristics, and lateral film position on the scanner (7) . There are published recommendations for accurate film dosimetry, notably AAPM Task Group 55 (8) and much work published in the literature to reduce uncertainties in specific aspects of film dosimetry techniques 9 , 10 , 11 , 12 , 13 . However, no prior publication has considered the uncertainty introduced in film dosimetry by film curling at the point of scanning, which is often undetected or deemed insignificant by the operator, but may introduce a substantial dose error.…”
Section: Introductionmentioning
confidence: 99%
“…(7) There are published recommendations for accurate film dosimetry, notably AAPM Task Group 55 (8) and much work published in the literature to reduce uncertainties in specific aspects of film dosimetry techniques. (9)(10)(11)(12)(13) However, no prior publication has considered the uncertainty introduced in film dosimetry by film curling at the point of scanning, which is often undetected or deemed insignificant by the operator, but may introduce a substantial dose error. Two commonly used flatbed scanners for film dosimetry, the Epson 10000XL and the Epson V750, both have a gap of several millimeters between the scanner glass plate and scanner lid which permits natural curling of film at scanning.…”
Section: Introductionmentioning
confidence: 99%