1991
DOI: 10.1021/ac00023a006
|View full text |Cite
|
Sign up to set email alerts
|

On-column laser-based refractive index detector for capillary electrophoresis

Abstract: The Interference pattern from side-illuminated capillary tubes has been exploited to develop a sensitive universal refractive Index (RI) detector suitable for nanollter on-column capillary separation techniques. A 2-fold benefit Is obtained by surrounding the capillary tube with a RI-matching fluid: the fringe pattern Is simplified, and thermal noise Is reduced. The key to RI detection In CE, provided that the instrument delivers sufficient sensitivity, has been found to be thermal stability. A thermal stabili… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

2
90
0

Year Published

1996
1996
2008
2008

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 99 publications
(92 citation statements)
references
References 37 publications
2
90
0
Order By: Relevance
“…Laser-based RI detection has, among others, been applied by Bornhop and co-workers [130][131][132] and Bruno et al [133,134]. The capillary flow cell developed by Bruno et al [134] is based on the so-called forward scatter, off-axis technique. With the use of an RImatching fluid surrounding the capillary flow cell, and active temperature control of the flow cell assembly, improved performance is feasible.…”
Section: Refractive Index Detectionmentioning
confidence: 99%
“…Laser-based RI detection has, among others, been applied by Bornhop and co-workers [130][131][132] and Bruno et al [133,134]. The capillary flow cell developed by Bruno et al [134] is based on the so-called forward scatter, off-axis technique. With the use of an RImatching fluid surrounding the capillary flow cell, and active temperature control of the flow cell assembly, improved performance is feasible.…”
Section: Refractive Index Detectionmentioning
confidence: 99%
“…This method has been successfully applied to HPLC, CE and flow-injection analysis. 29 The 'off-axis' method for CE was also demonstrated by Bruno et al 30 in the analysis of underivatized sugars in a 50 mm id capillary. They identified Joule heating as the major source of experimental noise.…”
mentioning
confidence: 89%
“…As UV absorption does not scale favorably due to path length dependency [12,15] and nonlinear response to sample concentration [16], effort is being directed towards maintaining high sensitivity with RID while scaling the detection volume down to the nanoliter regime. For example, Wang et al…”
Section: Microscale Separationmentioning