2006
DOI: 10.1021/ma0609174
|View full text |Cite
|
Sign up to set email alerts
|

Novel Starlike Amphiphilic Graft Copolymers with Hydrophilic Poly(acrylic acid) Backbone and Hydrophobic Poly(methyl methacrylate) Side Chains

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

5
42
0

Year Published

2006
2006
2014
2014

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 48 publications
(47 citation statements)
references
References 28 publications
5
42
0
Order By: Relevance
“…The size of micelle nanoparticles will be affected by the morphologies and the chain lengths of hydrophilic/hydrophobic segments, which is important for their biomedical applications [30,31]. Therefore, the morphologies, size and size distribution of the as-prepared copolymers micelles are investigated by TEM observations and DLS measurements, as illustrated in Table 2 and Fig.…”
Section: Tem Observation and Dls Determinationmentioning
confidence: 99%
“…The size of micelle nanoparticles will be affected by the morphologies and the chain lengths of hydrophilic/hydrophobic segments, which is important for their biomedical applications [30,31]. Therefore, the morphologies, size and size distribution of the as-prepared copolymers micelles are investigated by TEM observations and DLS measurements, as illustrated in Table 2 and Fig.…”
Section: Tem Observation and Dls Determinationmentioning
confidence: 99%
“…[8] However, most of the examples employ dendritic macroinitiators with a flexible structures such as PAMAM [9,10] or ether-based dendrimers. [11,12] Typically the attachment of the polymeric shell in these core-shell systems occurs by either a grafting-from [13] or grafting-onto [14] process. However, the requirement of a high exposure and reactivity of the functions at the macroinitiator periphery is often hampered by backfolding and deactivation.…”
Section: Introductionmentioning
confidence: 99%
“…Both the copolymers have about one hydrophobic PS chain in every 10 hydrophilic EO units, but the average length of hydrophobic PS chain of the star graft copolymer (17 St units) is shorter than that of the linear graft copolymer (22 units). And it has been proven that the shorter hydrophobic side chain results in higher cmc in the case of graft copolymer [13] while the star graft structure does not have distinct advantage in reducing cmc value than the linear graft structure [14].…”
Section: Measurement Of Critical Micelle Concentrationmentioning
confidence: 99%
“…However, the investigation of the self-assembly behaviors of star graft copolymers has been limited because of the difficulty in the synthesis of well-defined amphiphilic star graft copolymers with controlled molecular weights and low polydispersities [14]. Recently, star graft copolymers with three and four arms comprising poly(2-hydroxyethyl methacrylate) as main chain and poly(n-butyl acrylate) as side chains were synthesized by ATRP [15].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation