2001
DOI: 10.1039/b104047m
|View full text |Cite
|
Sign up to set email alerts
|

Novel flow injection strategies for study and control of matrix interferences by inductively coupled plasma time-of-flight mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
24
0

Year Published

2002
2002
2020
2020

Publication Types

Select...
5
2
1

Relationship

1
7

Authors

Journals

citations
Cited by 26 publications
(25 citation statements)
references
References 8 publications
(9 reference statements)
1
24
0
Order By: Relevance
“…Hence, the peaks for the different elements were divided point by point by those corresponding to an element (acting as IS). 34 This procedure was followed for the plain water solution and for the nitric acid, sodium and acetic acid solutions. Fig.…”
Section: Analytical Signalmentioning
confidence: 99%
“…Hence, the peaks for the different elements were divided point by point by those corresponding to an element (acting as IS). 34 This procedure was followed for the plain water solution and for the nitric acid, sodium and acetic acid solutions. Fig.…”
Section: Analytical Signalmentioning
confidence: 99%
“…136 The advantages of ICP-TOF-MS over sequential mass analyzers for fast transient detection and the simultaneous determination of a large number of isotopes in the flow injection (FI) peaks in trace metal analysis have been discussed. [137][138][139][140][141] The absence of spectral skew is highly appreciated. The applicability of a combined FI-hydride generation (HG)-ICP-TOF-MS system to the determination of As, Bi, Ge, Hg, Sb, Se and Sn in urine samples has been examined.…”
Section: Applications Of Icp-tof-ms Technique In Elemental Analysismentioning
confidence: 99%
“…The use of gradient dilution flow injection systems has been recommended for the identification of matrix effects and the reduction of interferences in FI-ICP-TOF-MS analysis. 140 Simultaneous ion extraction and full elemental coverage in ICP-TOF-MS provide significant improvement in the isotope ratio precision as compared with other mass spectrometric techniques. The great potential of ICP-TOF-MS for isotope ratios evaluation has been demonstrated.…”
Section: Applications Of Icp-tof-ms Technique In Elemental Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…Analyte signal enhancements or suppressions can be caused by concomitant species in the sample matrix, often resulting in serious errors. Although recognition and study of matrix effects are often difficult and time-consuming, exploiting the concentration change that occurs in a single flow-injection peak allows them to be studied by ICP-TOFMS (42). By creating a concentration gradient of a known interferent within a constant analyte concentration, signal enhancements or suppressions were monitored as a function of time and, therefore, matrix concentration.…”
Section: Mitigating Interferencesmentioning
confidence: 99%