2018
DOI: 10.1016/j.elecom.2018.01.018
|View full text |Cite
|
Sign up to set email alerts
|

Novel dual Pt-Pt/IrO ultramicroelectrode for pH imaging using SECM in both potentiometric and amperometric modes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
8
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
8
1
1

Relationship

1
9

Authors

Journals

citations
Cited by 35 publications
(11 citation statements)
references
References 23 publications
0
8
0
Order By: Relevance
“…This sensor was successfully applied to study the localized pH distribution during the corrosion of stainless steel in NaCl solution by SECM. The same group proposed a dual solid-state microelectrode that can be used in both amperometric and potentiometric SECM modes 156. As above,the amperometric mode allows one to control tip-substrate distance while the potentiometric mode provides information on ion distribution.…”
mentioning
confidence: 99%
“…This sensor was successfully applied to study the localized pH distribution during the corrosion of stainless steel in NaCl solution by SECM. The same group proposed a dual solid-state microelectrode that can be used in both amperometric and potentiometric SECM modes 156. As above,the amperometric mode allows one to control tip-substrate distance while the potentiometric mode provides information on ion distribution.…”
mentioning
confidence: 99%
“…As the difference between the models is relatively small and the experimental scans include the flat background substrate, the planar model is used herein when describing the Gram-negative bacterial scans. Note that although COMSOL Multiphysics can, in principle, be used for three-dimensional simulations, ,, the accuracy can be compromised and/or simulations become computationally expensive for complex problems, such as in this case, where there is an interplay of ion migration and electroosmotic fluid flow, and there is a need to consider charged interfaces. We thus retained a 2D model to assess the effect of a curved interface.…”
Section: Resultsmentioning
confidence: 99%
“…As the difference between the models is relatively small, and the experimental scans include the flat background substrate, the planar model is used herein when describing the gram-negative bacterial scans. Note that although COMSOL Multiphysics can, in principle, be used for 3-dimensional simulations, 21,41,42 the accuracy can be compromised and/or simulations become computationally expensive for complex problems, such as here, where there is an interplay of ion migration and electroosmotic fluid flow, and the need to consider charged interfaces. We thus retained a 2D model to assess the effect of a curved interface.…”
Section: Resultsmentioning
confidence: 99%