2018
DOI: 10.1021/acs.analchem.8b04681
|View full text |Cite
|
Sign up to set email alerts
|

Potentiometric Sensing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
144
0
3

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
3

Relationship

1
8

Authors

Journals

citations
Cited by 254 publications
(160 citation statements)
references
References 189 publications
(435 reference statements)
2
144
0
3
Order By: Relevance
“…A general treatment on electrochemical biosensors is beyond the scope of this paper as excellent dedicated reviews can be found in the recent literature. 22,[32][33][34] Here, only the most salient details that are relevant to the discussion of the amplification factors in electronic biosensors, will be highlighted. In particular, all the discussion of the biocatalytic reactions in enzyme based amperometric biosensors 35 will be omitted as we will focus only on a generic faradaic current generated by a redox active couple such as ferrocyanide.…”
Section: Materials Horizons Reviewmentioning
confidence: 99%
See 1 more Smart Citation
“…A general treatment on electrochemical biosensors is beyond the scope of this paper as excellent dedicated reviews can be found in the recent literature. 22,[32][33][34] Here, only the most salient details that are relevant to the discussion of the amplification factors in electronic biosensors, will be highlighted. In particular, all the discussion of the biocatalytic reactions in enzyme based amperometric biosensors 35 will be omitted as we will focus only on a generic faradaic current generated by a redox active couple such as ferrocyanide.…”
Section: Materials Horizons Reviewmentioning
confidence: 99%
“…However, just as an example, potentiometric sensors based on Molecularly Imprinted Polymer membranes have been successfully developed to sense organic compounds in their ionic and neutral forms. 33,38 Indeed, these membranes, have gained wide acceptance as new artificial recognition elements exhibiting affinity and selectivity comparable to those of natural recognition elements such as antibodies and enzymes. [39][40][41] These evidences show that a membrane of a potentiometric sensor can be designed to selectively detect not only an ionic species but also analytes such as antigens or DNA strands, that can or cannot bear a net charge.…”
Section: The Electrochemical Potentiometric Sensorsmentioning
confidence: 99%
“…One of the important factors that should be also taken under consideration by researchers while making this choice is the final application. In particular, we recently found that the new approximation proposed here to describe the mixed ion potentiometric response made it possible to analyze the time-dependent behavior of selectivity coefficients [13], which was not possible on the basis of other models previously described in the literature.…”
Section: Discussionmentioning
confidence: 96%
“…Various environment and health monitoring agencies have set the values for daily intake of nitrites by human in portable drinking water as 3 mg/L. Hence it is essential to monitor and check nitrite at trace levels from the environmental samples using ion selective electrodes [36, 37]. These ion selective electrodes can compete with the existing methods of trace analysis.…”
Section: Introductionmentioning
confidence: 99%