2007
DOI: 10.1016/j.athoracsur.2006.09.053
|View full text |Cite
|
Sign up to set email alerts
|

Novel Bioengineered Small Caliber Vascular Graft With Excellent One-Month Patency

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
17
0

Year Published

2008
2008
2019
2019

Publication Types

Select...
8
1
1

Relationship

0
10

Authors

Journals

citations
Cited by 20 publications
(17 citation statements)
references
References 22 publications
0
17
0
Order By: Relevance
“…Despite the variations in mechanical properties, all materials (with perhaps the exception of 12% PEI) retained mechanical properties that would be highly favorable for vascular graft applications. The tensile strength and elastic moduli of native arteries are approximately 1.4 and 1.5-3 MPa, respectively [5,48,49], while the PU-PEI materials described here possessed tensile strengths and moduli of 1.5-6 and 2.5-3 MPa, respectively. In contrast, ePTFE has a tensile strength of 27 MPa and an elastic modulus of 500 MPa, which are orders of magnitude different from the properties of the native vasculature.…”
Section: Discussionmentioning
confidence: 98%
“…Despite the variations in mechanical properties, all materials (with perhaps the exception of 12% PEI) retained mechanical properties that would be highly favorable for vascular graft applications. The tensile strength and elastic moduli of native arteries are approximately 1.4 and 1.5-3 MPa, respectively [5,48,49], while the PU-PEI materials described here possessed tensile strengths and moduli of 1.5-6 and 2.5-3 MPa, respectively. In contrast, ePTFE has a tensile strength of 27 MPa and an elastic modulus of 500 MPa, which are orders of magnitude different from the properties of the native vasculature.…”
Section: Discussionmentioning
confidence: 98%
“…Insertion of grafts 3 to 5 mm in diameter in the rabbit generally requires placement in the aortic 39,[136][137][138][139] or aortoiliac 38 position, although sizemismatched conduits up to 5 mm diameter have been placed in the CCA. 148,149 The disadvantage of aortic interposition grafting is the lack of an intra-animal control.…”
Section: Small-animal Models For the Assessment Of Novel Vascular Conmentioning
confidence: 99%
“…To this end, efforts to improve the haemocompatibility of various materials have often concentrated on designing systems to elute anticoagulants, such as heparin [10,11]. Heparin is a naturally occurring glycosaminoglycan (GAG) with antithrombotic properties.…”
Section: Introductionmentioning
confidence: 99%