2015
DOI: 10.1016/j.jelekin.2015.07.010
|View full text |Cite
|
Sign up to set email alerts
|

Noninvasive assessment of the activity of the shoulder girdle muscles using ultrasound real-time tissue elastography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
17
0
1

Year Published

2015
2015
2024
2024

Publication Types

Select...
8
2

Relationship

2
8

Authors

Journals

citations
Cited by 36 publications
(18 citation statements)
references
References 29 publications
0
17
0
1
Order By: Relevance
“…More importantly, if the reference range of the MD elasticity is established in healthy individuals using SWE, it may be helpful to further assess MD muscle strain. However, there is little research on the changes of MD elasticity during different shoulder abduction using SWE [9][10]. Moreover, studies on both the reference ranges of the normal MD elasticity and its potential factors are extremely lacking.…”
Section: Introductionmentioning
confidence: 99%
“…More importantly, if the reference range of the MD elasticity is established in healthy individuals using SWE, it may be helpful to further assess MD muscle strain. However, there is little research on the changes of MD elasticity during different shoulder abduction using SWE [9][10]. Moreover, studies on both the reference ranges of the normal MD elasticity and its potential factors are extremely lacking.…”
Section: Introductionmentioning
confidence: 99%
“…Of these, freehand sonoelastography has been shown to quantify the strain in tissues by measuring displacement under external mechanical compression (Niitsu et al, 2011). Using this technique, previous studies have assessed the material properties of shoulder muscles (Ishikawa et al, 2015, Muraki et al, 2015). Although studies have shown good feasibility and reliability of the technique, freehand compression with a consistent load still remains a technical challenge, with amplitude and/or velocity of loading compression yet to be established (Cantisani et al, 2015).…”
Section: Introductionmentioning
confidence: 99%
“…Surface electrodes may not be able to track the same area of the target muscle if skin displacement is large. For the scapular muscles, alternative methods such as fine-wire electrodes [40] and ultrasound elastography [41] may be useful to realize the measurement of muscle activity in a full range of shoulder elevation. Third, there was some potential for bias in the statistical analysis because the authors who performed the statistical analyses were not blinded to the purpose of the study.…”
Section: Discussionmentioning
confidence: 99%