Background Numerous structural and compositional changes – related not only to age, but also activity level and sex – may affect skeletal muscle stiffness across the adult age-span. Measurement techniques available thus far have largely limited passive stiffness evaluations to those of entire joints and muscle-tendon units. Shear wave elastography is an increasingly popular ultrasound technique for evaluating the mechanical properties of skeletal muscle tissue. The purpose of this study was to quantify the passive stiffness, or shear modulus, of the biceps brachii throughout adulthood in flexed and extended elbow positions. We hypothesized that shear modulus would be higher in males relative to females, and with advanced age in both sexes. Methods Shear wave elastography quantified biceps brachii stiffness at 90° elbow flexion and full extension in a large sample of adults between 21–94 years old (n=133; 47 males). Findings Regression analysis found sex and age were significant parameters for older adults (>60 years) in full extension. As expected, shear modulus values increased with advancing age; however, shear modulus values for females tended to be higher than those for males. Interpretation This study begins to establish normative trends for skeletal muscle shear modulus throughout adulthood. Specifically, this work establishes for the first time that the higher passive joint torque often found in males relative to females likely relates to parameters other than muscle shear modulus. Indeed, perhaps increases in skeletal muscle passive stiffness, though potentially altering the length-tension curve, serve a protective role – maintaining the tendon-muscle-tendon length-tension curve within a functional range.
Ultrasound imaging has been used to evaluate various shoulder pathologies, whereas, quantification of the rotator cuff muscle stiffness using shear wave elastography (SWE) has not been verified. The purpose of this study was to investigate the reliability and feasibility of SWE measurements for the quantification of supraspinatus (SSP) muscle elasticity. Thirty cadaveric shoulders (18 intact and 12 with torn rotator cuff) were used. Intra- and inter-observer reliability was evaluated on an established SWE technique for measuring the SSP muscle elasticity. To assess the effect of overlying soft tissues above the SSP muscle, SWE values were measured with the transducer placed on the skin, on the subcutaneous fat after removing the skin, on the trapezius muscle after removing the subcutaneous fat, and directly on the SSP muscle. In addition, SWE measurements on 4 shoulder positions (0°, 30°, 60°, and 90° abduction) were compared in those with/without rotator cuff tears. Intra- and inter-observer reliability of SWE measurements were excellent for all regions in SSP muscle. Also, removing the overlying soft tissue showed no significant difference on SWE values measured in the SSP muscle. The SSP muscle with 0° abduction showed large SWE values, whereas, shoulders with large-massive tear showed smaller variation throughout the adduction-abduction positions. SWE is a reliable and feasible tool for quantitatively assessing the SSP muscle elasticity. This study also presented SWE measurements on the SSP muscle under various shoulder abduction positions which might help characterize patterns in accordance to the size of rotator cuff tears.
Osteoporosis is characterized by bony material loss and decreased bone strength leading to a significant increase in fracture risk. Patient-specific quantitative computed tomography (QCT) finite element (FE) models may be used to predict fracture under physiological loading. Material properties for the FE models used to predict fracture are obtained by converting grayscale values from the CT into volumetric bone mineral density (vBMD) using calibration phantoms. If there are any variations arising from the CT acquisition protocol, vBMD estimation and material property assignment could be affected, thus, affecting fracture risk prediction. We hypothesized that material property assignments may be dependent on scanning and postprocessing settings including voltage, current, and reconstruction kernel, thus potentially having an effect in fracture risk prediction. A rabbit femur and a standard calibration phantom were imaged by QCT using different protocols. Cortical and cancellous regions were segmented, their average Hounsfield unit (HU) values obtained and converted to vBMD. Estimated vBMD for the cortical and cancellous regions were affected by voltage and kernel but not by current. Our study demonstrated that there exists a significant variation in the estimated vBMD values obtained with different scanning acquisitions. In addition, the large noise differences observed utilizing different scanning parameters could have an important negative effect on small subregions containing fewer voxels.
The deltoid muscle plays a critical role in the biomechanics of shoulders undergoing reverse shoulder arthroplasty (RSA). However, both pre- and postoperative assessment of the deltoid muscle quality still remains challenging. The purposes of this study were to establish a novel methodology of shear wave elastography (SWE) to quantify the mechanical properties of the deltoid muscle, and to investigate the reliability of this technique using cadaveric shoulders for the purpose of RSA. Eight fresh-frozen cadaveric shoulders were obtained. The deltoid muscles were divided into 5 segments (A1, A2, M, P1 and P2) according to the muscle fiber orientation and SWE values were measured for each segment. Intra- and inter-observer reliability was evaluated using intraclass correlation coefficient (ICC). To measure the response of muscle tension during RSA, the humeral shaft was osteotomized and subsequently elongated by an external fixator (intact to 15 mm elongation). SWE of the deltoid muscle was measured under each stretch condition. Intra- and inter-observer reliability of SWE measurements for all regions showed 0.761–0.963 and 0.718–0.947 for ICC(2,1). Especially, SWE measurements for segments A2 and M presented satisfactory repeatability. Elongated deltoid muscles by the external fixator showed a progressive increase in passive stiffness for all muscular segments. Especially, SWE outcomes of segments A2 and M reliably showed an exponential growth upon stretching (R2 = 0.558 and 0.593). Segmental measurements using SWE could be reliably and feasibly used to quantitatively assess the mechanical properties of the deltoid muscle, especially in the anterior and middle portions. This novel technique based on the anatomical features may provide helpful information of the deltoid muscle properties during treatment of RSA.
Study Design Vertebral fracture load and stiffness from a metastatic vertebral defect model were predicted using nonlinear finite element models (FEM) and validated experimentally. Objective The study objective was to develop and validate an FEM-based tool for predicting polymer-augmented lytic vertebral fracture load and stiffness and the influence of metastatic filling materials. Summary of Background Data Percutaneous vertebroplasty has the potential to reduce vertebral fracture risk affected with lytic metastases by providing mechanical stabilization. However, it has been shown that the mismatch in mechanical properties between poly(methyl-methacrylate) (PMMA) and bone induces secondary fractures and intervertebral disc degeneration. A biodegradable co-polymer, poly(propylene fumarate-co-caprolactone) [P(PF-co-CL)], has been shown to possess the appropriate mechanical properties for bone defect repair. Methods Simulated metastatic lytic defects were created in 40 cadaveric vertebral bodies, which were randomized into four groups: intact vertebral body (Intact), simulated defect without treatment (Negative), defect treated with P(PF-co-CL) (Co-polymer), and defect treated with PMMA (PMMA). Spines were imaged with quantitative computerized tomography (QCT), and QCT/FEM-subject-specific, non-linear models were created. Predicted fracture loads and stiffness were identified and compared to experimentally measured values using Pearson’s correlation analysis and paired t-test. Results There was no significant difference between the measured and predicted fracture loads and stiffness for each group. Predicted fracture loads were larger for PMMA-augmentation (3960 N (1371 N)) compared to that of the co-polymer, negative and intact groups (3484 N (1497 N), 3237 N (1744 N) and 1747 N (702 N)). A similar trend was observed in the predicted stiffness. Moreover, predicted and experimental fracture loads were strongly correlated (R2 = 0.78), while stiffness showed moderate correlation (R2 = 0.39). Conclusion QCT/FEM was successful for predicting fracture loads of metastatic, polymer-augmented vertebral bodies. Overall, we have demonstrated that QCT/FEM may be a useful tool for predicting in situ vertebral fracture load resulting from vertebroplasty.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.