2013
DOI: 10.1103/physrevstab.16.062801
|View full text |Cite
|
Sign up to set email alerts
|

Noninterceptive method to measure longitudinal Twiss parameters of a beam in a hadron linear accelerator using beam position monitors

Abstract: A new method of measuring of the rms longitudinal Twiss parameters of a beam in linear accelerators is presented. It is based on using sum signals from beam position monitors sensitive to the longitudinal charge distribution in the bunch. The applicability of the method is demonstrated on the superconducting section of the Oak Ridge Spallation Neutron Source linear accelerator. The results are compared to a direct measurement of the bunch longitudinal profiles using an interceptive bunch shape monitor in the l… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
7
0
1

Year Published

2016
2016
2019
2019

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(8 citation statements)
references
References 4 publications
(6 reference statements)
0
7
0
1
Order By: Relevance
“…After combining (1) and 6, it gives a set of linear equations with the measured amplitudes on the left side and four unknown parameters hφ 2 ini i, hφ ini • E ini i, hE 2 ini i, 2 lnðA max Þ on the right side:…”
Section: Extension Of the Original Methodsunclassified
See 3 more Smart Citations
“…After combining (1) and 6, it gives a set of linear equations with the measured amplitudes on the left side and four unknown parameters hφ 2 ini i, hφ ini • E ini i, hE 2 ini i, 2 lnðA max Þ on the right side:…”
Section: Extension Of the Original Methodsunclassified
“…Increasing N reduces the error of solution. The error analysis, and relations between initial statistical correlation in the bunch and Twiss parameters is described in the appendix of [1]. It should be noted that the system of equations (7) does not have solutions for a lattice with only one rf cavity and one drift like in the original method in [1].…”
Section: Extension Of the Original Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Due to the rather low beam energy at the LBM3 location, there is a concern regarding a sufficient photon yield from transition or Cherenkov radiation. Therefore it is foreseen to use the new method proposed in [72] for this location, either as a supplementary option or as a back-up solution. Eleven wire scanners are installed in the linac at different locations.…”
mentioning
confidence: 99%