1993
DOI: 10.1002/j.2050-0416.1993.tb01146.x
|View full text |Cite
|
Sign up to set email alerts
|

Nephelometry as a Method for Studying the Relations Between Polyphenols and Proteins

Abstract: The conditions to be fulfilled by a nephelometer intended to tackle the problems of the colloidal stability of beers are reviewed in the light of 30 years of original work in the author's laboratory. Emphasis is put on the various methods involving the kinetics of the formation of the proteotannic hazes which can be studied from either the proteinic side or the polyphenolic side. They are all simple, quick, sensitive, inexpensive yet highly discriminant methods some of them being routinely used for many years … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
36
1
4

Year Published

2002
2002
2021
2021

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 62 publications
(41 citation statements)
references
References 4 publications
0
36
1
4
Order By: Relevance
“…Perhaps of rather more value are tests in which colloidally sensitive materials are forced out of solution. The most famous of these is the Chapon test 30 , in which a sample of beer is chilled to -8°C without freezing (added alcohol prevents freezing) and left for 8 hours before the chill haze is measured. This type of test is especially valuable because any material that displays a tendency to fall out of solution is likely to be detected in this test, which combines the very low temperature and the added precipitant (ethanol).…”
Section: Predicting the Colloidal Shelf Life Of Beermentioning
confidence: 99%
“…Perhaps of rather more value are tests in which colloidally sensitive materials are forced out of solution. The most famous of these is the Chapon test 30 , in which a sample of beer is chilled to -8°C without freezing (added alcohol prevents freezing) and left for 8 hours before the chill haze is measured. This type of test is especially valuable because any material that displays a tendency to fall out of solution is likely to be detected in this test, which combines the very low temperature and the added precipitant (ethanol).…”
Section: Predicting the Colloidal Shelf Life Of Beermentioning
confidence: 99%
“…Je zaměřena na hledání korelace mezi vývojem obsahu tanoidů stanoveným metodou dle Chapona [11] a vývo-jem chladového zákalu během zrychleného stárnutí [12] ředěného a neředěného HGB piva s cílem získat detailnější analytické informace o příčinách koloidní nestability finálně stočeného produktu [13,14]. Pro ilustraci je studie doplněna o výsledky testů obsahu citlivých bílkovin (titrací taninem) a stanovení prahu precipitace bílkovin (titrací nasyceným roztokem síranu amonného) [15].…”
Section: úVodunclassified
“…Po korekci na hranici rozlišitelnosti stanovení tanoidů (okolo 10 mg PVP/l) [15] jsou počáteční hodnoty obsahu tanoidů ředěného piva v korelaci s ředicím poměrem. Tento výsledek je ve shodě s měřeními McMurrougha [18].…”
Section: Tanoidyunclassified
“…Tannoids include low and medium molecular weight polyphenols, the polymers of catechin and antho-cyanogens. The tannoid content of beer, wort, barley, malt and hop extracts can be determined by precipitation with PVP 7,8 . This polymer, which can be considered as a structural analogue of proteins, binds with tannoids to give rise to haze.…”
Section: Introductionmentioning
confidence: 99%