2021
DOI: 10.1016/j.foodchem.2021.129042
|View full text |Cite
|
Sign up to set email alerts
|

Nanographene oxide modified phenyl methanethiol nanomagnetic composite for rapid separation of aluminum in wastewaters, foods, and vegetable samples by microwave dispersive magnetic micro solid-phase extraction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
16
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 25 publications
(16 citation statements)
references
References 38 publications
0
16
0
Order By: Relevance
“…The overall chemical fractionation between 237 Np and 242 Pu for the whole analytical procedure was 0.974 AE 0.064 (k ¼ 2), allowing 237 Np and Pu isotopes to be measured using 242 Pu as a yield tracer with yields of 76 AE 5%. The ICP-MS/MS LODs were 0.025, 0.025, 0.015, and 0.020 fg mL À1 for 237 Np, 239 Pu, 240 Pu and 241 Pu, respectively, for a 20 mL urine sample. The method was validated by the analysis of three Pu-spiked urine reference materials from the Association for the Promotion of Quality Control in Radiotoxicological Analysis (PROCORAD), France, and by comparison of results with those obtained by conventional alpha spectrometry.…”
Section: Digestion Extraction and Pre-concentrationmentioning
confidence: 92%
See 1 more Smart Citation
“…The overall chemical fractionation between 237 Np and 242 Pu for the whole analytical procedure was 0.974 AE 0.064 (k ¼ 2), allowing 237 Np and Pu isotopes to be measured using 242 Pu as a yield tracer with yields of 76 AE 5%. The ICP-MS/MS LODs were 0.025, 0.025, 0.015, and 0.020 fg mL À1 for 237 Np, 239 Pu, 240 Pu and 241 Pu, respectively, for a 20 mL urine sample. The method was validated by the analysis of three Pu-spiked urine reference materials from the Association for the Promotion of Quality Control in Radiotoxicological Analysis (PROCORAD), France, and by comparison of results with those obtained by conventional alpha spectrometry.…”
Section: Digestion Extraction and Pre-concentrationmentioning
confidence: 92%
“…The method was validated by the analysis of three Pu-spiked urine reference materials from the Association for the Promotion of Quality Control in Radiotoxicological Analysis (PROCORAD), France, and by comparison of results with those obtained by conventional alpha spectrometry. The procedure developed successfully measured the concentrations of 237 Np, 239 Pu, 240 Pu, and 241 Pu in urine samples collected during decorporation therapy with DTPA, following a Pu inhalation exposure accident in Japan. The researchers concluded that the method developed (twelve 20 mL samples in 9 h) was superior to the alpha spectrometry method, that required 500 mL of sample and took one week for 2 samples.…”
Section: Digestion Extraction and Pre-concentrationmentioning
confidence: 99%
“…After 20 min stirring, the product was cooled at 25°C. Finally, the black Fe 3 O 4 -ATPyHS@GO was centrifuged at 4000 rpm for 50 min, washed for 10 times (DW) and dried at 70 °C based on vacuum accessory [22][23][24].…”
Section: Synthesis Of Fe 3 O 4 -Atpyhs@gomentioning
confidence: 99%
“…Moreover, the peak of 1400 cm -1 and 2234 cm -1 related to tertiary hydroxyl groups(OH) and HS function on GO. In -addition the peaks at 628 cm -1 and 583 cm -1 belong to the Iron oxide [22][23][24].…”
Section: Ftir Diagrammentioning
confidence: 99%
See 1 more Smart Citation