2011
DOI: 10.1016/j.bios.2010.11.053
|View full text |Cite
|
Sign up to set email alerts
|

Nanocrystalline diamond impedimetric aptasensor for the label-free detection of human IgE

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
49
0
1

Year Published

2011
2011
2020
2020

Publication Types

Select...
7
2

Relationship

4
5

Authors

Journals

citations
Cited by 76 publications
(50 citation statements)
references
References 36 publications
0
49
0
1
Order By: Relevance
“…Efficient surface treatments also permit to conjugate ND surfaces with fluorescent molecules [202][203][204][205], with DNA [206], siRNA [27], proteins [207,208], lysozymes [208], growth hormones [209], antibodies [210,211], anti-cancer drugs [30][31][32], as well as with dopamine derivatives [212].…”
Section: Grafting Of Biological Moietiesmentioning
confidence: 99%
“…Efficient surface treatments also permit to conjugate ND surfaces with fluorescent molecules [202][203][204][205], with DNA [206], siRNA [27], proteins [207,208], lysozymes [208], growth hormones [209], antibodies [210,211], anti-cancer drugs [30][31][32], as well as with dopamine derivatives [212].…”
Section: Grafting Of Biological Moietiesmentioning
confidence: 99%
“…Standard optical fibers have emerged over the years as excellent alternatives that can compete with the sensitivity and specificity of prism-based SPR sensors, while offering the advantage of low cost and small size greatly desired for developing a POC tool. One such platform, namely fiber optic surface plasmon resonance (FO-SPR), has been previously described by our group as a promising biosensor for protein-and DNA-based assays (Delport et al 2012;Janssen et al 2012;Knez et al 2013;Knez et al 2014;Pollet et al 2011;Pollet et al 2009;Tran et al 2011). The FO-SPR biosensor makes use of multimode optical fibers that facilitate SPR generation and enable implementation of bioassays.…”
Section: Introductionmentioning
confidence: 99%
“…The selective antigen recognition was analyzed in real-time, and the detection limit was found to be 10 nM, which was in the physiologically relevant range, and could be discriminated within 10 minutes (Bijnens et al, 2009). Tran et al (2011) described an impedimetric aptasensor for the detection of human IgE. Human IgE has been demonstrated to be a mediator in allergic reactions.…”
Section: Impedimetric Immunosensorsmentioning
confidence: 99%
“…IgE aptamers were covalently attached to NCD electrodes, and the impedimetric response was monitored continuously during IgE incubation. They obtained a detection limit of 0.03 µg/ml in serum (Tran et al, 2011).…”
Section: Impedimetric Immunosensorsmentioning
confidence: 99%