Monte Carlo-based Stochastic Analysis Results for Coordination of Single-Phase Rooftop PVs in Low Voltage Residential Networks

Abstract: Installation of single-phase rooftop photovoltaic (PV) systems in low voltage (LV) residential feeders without controlling their ratings and locations may deteriorate the overall grid performance including reversed power flows, high losses and unacceptable voltage profiles. Therefore, in recent years the utilities have adopted limitations on the maximum allowable number of PVs in LV networks. To overcome these issues, this paper investigates the performance of a communication-based and intelligent voltage prof… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(8 citation statements)
references
References 25 publications
0
8
0
Order By: Relevance
“…V P,K Є {V AC,P,K , V DC,P,K } depends on whether the feeder analysed is AC or DC type. The instantaneous values of DER DC link voltage, V LINK,P,K (t) (within the power conditioning unit installed at the premises), are given by the below equation (see (10)) . Where α P,K = 1, if DERs are present within the household premises; P DER,P,K (t) is the instantaneous DER power output in AC or DC distribution feeder; P DC,P,K (t) and S AC,P,K (t) are the instantaneous power demand by DC and AC loads, respectively, in the household premises located at phase P and pole K of the AC or DC radial distribution feeders.…”
Section: Distributed Energy Resources Integrated LV Hybrid Dc/ac Distmentioning
confidence: 99%
See 3 more Smart Citations
“…V P,K Є {V AC,P,K , V DC,P,K } depends on whether the feeder analysed is AC or DC type. The instantaneous values of DER DC link voltage, V LINK,P,K (t) (within the power conditioning unit installed at the premises), are given by the below equation (see (10)) . Where α P,K = 1, if DERs are present within the household premises; P DER,P,K (t) is the instantaneous DER power output in AC or DC distribution feeder; P DC,P,K (t) and S AC,P,K (t) are the instantaneous power demand by DC and AC loads, respectively, in the household premises located at phase P and pole K of the AC or DC radial distribution feeders.…”
Section: Distributed Energy Resources Integrated LV Hybrid Dc/ac Distmentioning
confidence: 99%
“…Stochastic MC-based sweep backward-forward load flow analysis technique is used to analyse the proposed distribution structure (Fig. 3) [10,22,23]. Self (in the case of both AC and DC networks) and mutual (only for AC distribution networks) impedance of distribution feeder conductors is calculated via modified Carson's equations [24].…”
Section: Stochastic MC Load Flow Analysismentioning
confidence: 99%
See 2 more Smart Citations
“…The high penetration level of DG units and large single-phase loads might lead to various problems and operational limit faults in electric power distribution systems. Although voltages are usually well balanced at the supply side, they can become unbalanced at the customer side due to the unequal system impedances, non-uniform distribution of single-phase loads and DG units [3][4][5].…”
Section: Introductionmentioning
confidence: 99%